Prices plus VAT plus shipping costs of 4,95 to GER (incl. VAT)
Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)
| P - Pressure range: | ||
| Quantity: |
- Order number: 801511-1032
Advantages
- We are ready to deliver: All information here
- Advice directly from experts
- Quality directly from the manufacturer
- Long-term stable temperature probes over years
- B2B wholesale customers welcome: All information here
- Swiss customers welcome: All information here
Our staff will be happy to help you
Pius Schneider
tel:+4976539659771
mailto:pschneider@testo-sensor.de
The pressure transmitter housing high bottom is ideal for precise measurement of differential pressure in ventilation and air conditioning systems, clean rooms, or for filter monitoring. Eight switchable measuring ranges and two output signals (0 to 10 V or 4 to 20 mA) ensure flexible application options. The robust housing with connections on the underside complies with protection class IP67 and is easy to install, even in confined spaces. Manual zero point adjustment ensures accurate measurement results at all times.
Here you can find our downloads for Pressure transmitter housing high bottom
| Data sheet Pressure transmitter housing high bottom | |
| Instruction manual Pressure transmitter housing high bottom | |
| Declaration of Conformity Pressure transmitter housing high bottom | |
Pressure transmitter - Supply and output | ||||||||||||||||
| Output | 0 - 10 V or 4 - 20 mA (via DIP switch) | |||||||||||||||
| Load resistance | Rl > 25 kOhm for voltage output | |||||||||||||||
| Load | Ra (Ohm) = 25 Ohm to 450 Ohm for current output | |||||||||||||||
| Signal filtering | Switchable 1 s / 10 s (via DIP switch) | |||||||||||||||
| Power consumption | < 1 W / 24 V DC; < 2 VA / 24 V AC | |||||||||||||||
| Power input | < 45 mA | |||||||||||||||
| Voltage supply | 24 V AC / DC (± 10 %) | |||||||||||||||
Pressure transmitter - Pressure | ||||||||||||||||
| Pressure type | Differential pressure | |||||||||||||||
| Measuring function | Differential pressure, volume flow (square root output signal) | |||||||||||||||
| Pressure range selectable | max. ± 100 Pa max. ± 1000 Pa max. ± 5000 Pa max. ± 10000 Pa | |||||||||||||||
| Measuring range | multi-range switching with 8 switchable measuring ranges | |||||||||||||||
| Accuracy pressure | typically ± 3 Pa (at ±100 Pa), ± 10 Pa (at ±1000 Pa), ± 35 Pa (at ±5000 Pa) at +25 °C | |||||||||||||||
| Zero offset | ± 10 % Measuring range | |||||||||||||||
| Linearity | < ± 1 % EW | |||||||||||||||
| Hysteresis | 0,3 % EW | |||||||||||||||
| Overpressure / underpressure | ± 50 kPa | |||||||||||||||
Pressure transmitter - Ambient conditions | ||||||||||||||||
| Storage temperature | -30 °C to +80 °C | |||||||||||||||
| Operating temperature | -20 °C to +50 °C | |||||||||||||||
| Permissible air humidity | < 95 % r. H., non-precipitating air< 95 % RH, non-condensing air | |||||||||||||||
| Medium temperature | -20 °C to +50 °C (temperature compensated 0 °C to 50 °C) | |||||||||||||||
| Medium | clean air and non-aggressive, non-flammable gases | |||||||||||||||
| Temperature drift | ± 0.1 % per °C EW | |||||||||||||||
| Long-term stability | ± 1 % / year | |||||||||||||||
Pressure transmitter - Certifications / Standards | ||||||||||||||||
| Protection class | III (according to EN 60 730) | |||||||||||||||
| Protection type | IP 67 according to EN 60 529 | |||||||||||||||
| Standards | CE conformity according to EMC Directive 2014/ 30/ EU | |||||||||||||||
Pressure transmitter - Technical drawing | ||||||||||||||||
![]() | ||||||||||||||||
Pressure transmitter - Housing | ||||||||||||||||
| Material | Plastic, UV-resistant Material polyamide, 30 % glass bead reinforced | |||||||||||||||
| Dimensions (L/W/H) (mm) | 72 x 64 x 37,8 | |||||||||||||||
| Color | Traffic white (similar to RAL9016) | |||||||||||||||
| Wetted parts | Brass, Ni, thermoset, Si, epoxy, RTV, BSG, UV silicone gel | |||||||||||||||
| Electrical connection | 0.14 - 1.5², via screw terminals on circuit board | |||||||||||||||
| Closure | with quick release screws | |||||||||||||||
| Pressure connection | with connection piece for pressure hose ⌀ 6 mm | |||||||||||||||
| Electrical connection | 0.14 - 1.5 mm², via screw terminals on circuit board | |||||||||||||||
| Screw connection | Cable gland, Plastic, M20x1,5, Strain relief, replaceable, max. 10,4 mm ⌀ Inner | |||||||||||||||
Pressure transmitter - Important assembly instructions | ||||||||||||||||
![]() | ||||||||||||||||
| [A] Negative pressure | ||||||||||||||||
| The device is supplied with the connection set (hoses and connection nipples). The pressure connections must be connected correctly according to the required monitoring type (see diagram). Before commissioning, check the pressure lines and electrical wiring for leaks. | ||||||||||||||||
Pressure transmitter - Delivery | ||||||||||||||||
| Delivery | Transmitter, Operating instructions | |||||||||||||||
| Packing | individually packed in cardboard box | |||||||||||||||
| Output: | 0-10 V, 4-20 mA |
| Gehäuse: | Housing without display |
| Messgröße: | Differential pressure |
| Schutzart: | IP 67 acc. EN 60 529 |
| Type: | Differential pressure transmitter |
- Download Datenblatt Druckmessumformer Gehäuse High Unten
- Download Datasheet Pressure transmitter housing high bottom
- Download Bedienungsanleitung Druckmessumformer Gehäuse High Unten
- Download Konformitätserklärung Druckmessumformer Gehäuse High Unten
- Download Datenblatt Druckmessumformer Gehäuse High Unten
- Download Datasheet Pressure transmitter housing high bottom
- Download Bedienungsanleitung Druckmessumformer Gehäuse High Unten
- Download Konformitätserklärung Druckmessumformer Gehäuse High Unten
S+S Regeltechnik GmbH
Thurn-und-Taxis-Str. 22
90411 Nürnberg
E-Mail mail[at]SplusS.de