Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Differential pressure switch

Differential pressure switch
€ 17,85 *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to NL, BE, AT (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
P - Pressure range

/* obj[key].surcharge*tax_factor; */
if (typeof obj[key] !== 'undefined') {
var key_total ='o_quantity_total', selector;
var total_quantity = obj[key_total].value;
/* in der gewünschten Optionsgruppe in allen Optionen die Bestellmenge auf total_quantity setzen */
selector = '*[data-groupid=\'' + key +'\']';
if ($(selector).length > 0) {
$(selector).attr('data-quantity', total_quantity);
}
obj[key].surcharge*total_quantity*tax_factor;
} else {0;}

keine Auswahl
(P0030) 20 Pa to 300 Pa
(P0050) 50 Pa to 500 Pa
(P0100) 100 Pa to 1000 Pa
(P0200) 500 Pa to 2000 Pa
(P0500) 1000 Pa to 5000 Pa
Q - Equipment

/* obj[key].surcharge*tax_factor; */
if (typeof obj[key] !== 'undefined') {
var key_total ='o_quantity_total', selector;
var total_quantity = obj[key_total].value;
/* in der gewünschten Optionsgruppe in allen Optionen die Bestellmenge auf total_quantity setzen */
selector = '*[data-groupid=\'' + key +'\']';
if ($(selector).length > 0) {
$(selector).attr('data-quantity', total_quantity);
}
obj[key].surcharge*total_quantity*tax_factor;
} else {0;}

(Q01) With mounting bracket
(Q02) With mounting ring
R - Connection kit
(R01) with ASD-06
(R02) without ASD-06
Image Changer
2.How many transmitter do you need?
Price calculation
Basic price
€ 17,85
P - Pressure range:  
Q - Equipment:  
R - Connection kit:  
Quantity:  
Configuration is incomplete - please check it!
  • 801410-1030
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our staff will be happy to help you
Pius Schneider
tel:+4976539659771
mailto:pschneider@testo-sensor.de
The differential pressure switch is used for reliable monitoring of differential, overpressure,...more
Product information "Differential pressure switch"

The differential pressure switch is used for reliable monitoring of differential, overpressure, or underpressure in air ducts and supply and exhaust air systems with non-aggressive, non-flammable gases. The switching point is factory-calibrated and can be precisely adjusted using an internal scale. Depending on the version, the device is equipped with a mounting bracket or mounting ring and can be installed flexibly. Different selectable pressure ranges cover common applications such as filter monitoring, air flow control or fan monitoring. A suitable connection set for direct use is available as an option.

Here you can find our downloads for Differential pressure switch

pdf-download Data sheet Differential pressure switch
pdf-download Instruction manual Differential pressure switch
pdf-download Declaration of Conformity Differential pressure switch
 

Pressure transmitter - Supply and output

Switching loads (contact load) 5 (0,8) A; 250 V AC; 4 (0,7) A, 30 V DC
Contact Single-pole, potential-free changeover switch (DDC suitable)
 

Pressure transmitter - Pressure

Pressure type Differential pressure
Pressure range selectable 20 Pa to 300 Pa
50 Pa to 500 Pa
100 Pa to 1000 Pa
500 Pa to 2000 Pa
1000 Pa to 5000 Pa
Lifespan Mechanical >10⁶ switching cycles
Membrane Silicone, LSR (Liquid Silicon Rubber)
 

Pressure transmitter - Ambient conditions

Storage temperature -40 °C to +85 °C
Operating temperature -30 °C to +85 °C
Permissible air humidity < 90 % r. H., non-precipitating air
Medium temperature -30 °C to +85 °C
Medium clean air and non-aggressive, non-flammable gases
 

Pressure transmitter - Certifications / Standards

Protection class II (according to EN 60 730)
Protection type IP 54 according to EN 60 529 with cover
Standards CE conformity
according to Low Voltage Directive 2014/ 35/ EU
Tests DVGW (according to DIN 1854)
VDE 0630
EN 61058
Gas Appliances Directive 2009 / 142 / EU
CE 0085 A P 0918
 

Pressure transmitter - Technical drawing

With mounting bracket
With mounting ring
 

Pressure transmitter - Equipment selectable

With mounting bracket
Material Steel sheet
Fastening 2 x Ø 5,1 mm & 2 x Ø 5,5 mm drill holes
Length (mm) 65
Width (mm) 42
With mounting ring
Fastening 4 x Ø 4,5 mm drill holes
Diameter (mm) 93
 

Pressure transmitter - Connection kit selectable

with ASD-06
2x connection nipples
Material ABS
Fastening 2 x Ø 3,5 mm drill holes
4x Phillips screws
Phillips screws Phillips screws (no pre-drilling necessary)
1x pipe
Material PVC
Length (mm) 2000
 

Pressure transmitter - Housing

Material Lower section: PC material (10% GF)
Snap-on lid: Material PC
Dimensions (L/W/H) (mm) 81 x 80,5 x 55
Color Lower section: light gray (similar to RAL7035) | Transparent snap-on lid
Closure with snap-on lid
Pressure connection with connection piece for pressure hose ⌀ 6 mm
Electrical connection 0.14 - 1.5 mm², via twist-proof screw terminals
Process connection using metal brackets or mounting rings
 

Pressure transmitter - Important assembly instructions


[A] Negative pressure:
P1 (+) is not connected, is open to the atmosphere on the air side P2 (-) connection in the duct
P2 (-) connection in the duct
[B] Filter:
P1 (+) connection before the filter
P2 (-) connection after the filter
[C] Fan:
P1 (+) connection before the fan
P2 (-) connection after the fan
The pressure connections are marked on the pressure switch with P1 (+) for higher pressure and P2 (-) for lower pressure.
Installation can be carried out using either the mounting angle bracket or mounting ring supplied. The recommended installation position is vertical with the pressure connections facing downwards (calibrated at the factory); horizontal installation with the cover facing upwards or downwards is also possible. Before commissioning, check the pressure lines and electrical connections for leaks and ensure that they are correctly connected.
 

Pressure transmitter - Delivery

Delivery Transmitter, Operating instructions, Mounting accessories
Packing individually packed in cardboard box
Properties
Gehäuse: Housing without display
Output: Schalter
Messgröße: Differential pressure
Schutzart: IP 54 acc. EN 60 529 with cover
Type: Differenzdruckschalter
Process connection: mittels Metallwinkel oder Montagering
Related links to "Differential pressure switch"
Available downloads:
Information about the manufacturer

S+S Regeltechnik GmbH
Thurn-und-Taxis-Str. 22
90411 Nürnberg
E-Mail mail[at]SplusS.de

Read, write and discuss reviews...more
Customer evaluation for "Differential pressure switch"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Pressure transmitter housing high top Pressure transmitter housing high top
€ 114,06 *
Order number: 801510-1032
Add to shopping cart
Pressure transmitter housing high bottom Pressure transmitter housing high bottom
€ 106,48 *
Order number: 801511-1032
Add to shopping cart
Pressure transmitter housing bottom Pressure transmitter housing bottom
€ 95,54 *
Order number: 801512-1032
Add to shopping cart
Pressure transmitter high 0-10 V Pressure transmitter high 0-10 V
€ 264,54 *
Order number: 801514-1033
Add to shopping cart
Pressure transmitter high 4-20 mA Pressure transmitter high 4-20 mA
€ 264,54 *
Order number: 801514-1032
Add to shopping cart