C - Mounting length: | ||
Quantity: |
- Order number: 807003-0012
Advantages
- We are ready to deliver: All information here
- Advice directly from experts
- Quality directly from the manufacturer
- Long-term stable temperature probes over years
- B2B customers welcome: All information here
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
The precise Pt1000 plug-in transmitter reliably measures temperatures in ducts and ventilation systems and provides a standardized 4-20 mA output signal. Thus, measured values are transmitted error-free even over long distances. Select the length of the protection sleeve. Measuring range and scaling are easily adjustable via DIP switch. The innovative rotary cover lock enables fast and secure mounting. Due to its robust design, the transmitter is ideal for temperature measurements in gaseous media, e.g. in ducts. Accessories such as immersion sleeves, compression fittings and mounting flanges made of stainless steel, aluminum or plastic are available in our online store.
Here you can find our downloads for Plug-in transmitter Basic 4-20 mA
Plug-in transmitter - Special features | ||||||||||||||||
Inputs and outputs | Input: Pt1000 resistance sensor, permanently installed Output: 4 to 20 mA | |||||||||||||||
Accuracy & Long-term stability | Accuracy: high measuring accuracy Long-term stability: long service life with flexible application possibilities | |||||||||||||||
Design | Compact, robust, vibration and shock resistant design Easy mounting thanks to innovative twist-cover closure / bayonet lock | |||||||||||||||
Parametrization | Simple and super-fast parameterization thanks to preset dip switches | |||||||||||||||
Alarm function | Sensor break monitoring Sensor short-circuit monitoring Measuring range monitoring | |||||||||||||||
Plug-in transmitter - Measuring element | ||||||||||||||||
Measuring element | Norm | Configurable measuring range | Accuracy | |||||||||||||
Pt1000 | IEC 60751 | -200 °C to +850 °C | -328 °F to +1562 °F | ±0.3 °C + 0.1 % of the measuring span | |||||||||||||
Connection type | 2-wire (permanently installed) | |||||||||||||||
Plug-in transmitter - Output | ||||||||||||||||
Output type | analog, temperature linear for RTD | |||||||||||||||
Output signal | 4 to 20 mA | |||||||||||||||
Parametrization / Scaling | Configurable via DIP-Switch | |||||||||||||||
Resolution | 16 bit dac | |||||||||||||||
Accuracy (°C) | 0,1 | |||||||||||||||
Load | 500 Ω at 24 VDC | |||||||||||||||
Connection type | 2-wire | |||||||||||||||
Plug-in transmitter - Time response | ||||||||||||||||
Closing time (s) | ≤ 5 | |||||||||||||||
Heating period | The specified accuracy is reached after max. 4 minutes | |||||||||||||||
Signal attenuation (s) | 0 – 30 | |||||||||||||||
Measuring cycle (s) | <0,25 ( < 4 Hz ) | |||||||||||||||
Response time | Depending on sensor type | |||||||||||||||
Plug-in transmitter - Sensor monitoring & sensor error | ||||||||||||||||
Sensor failure effects | according to NAMUR NE43 | |||||||||||||||
Plug-in transmitter - Alarms | ||||||||||||||||
Sensor error | 4 - 20 mA | |||||||||||||||
Sensor Status | 3,6 mA | |||||||||||||||
Sensor short circuit | 21 mA | |||||||||||||||
Plug-in transmitter - Measured values outside the measuring range | ||||||||||||||||
Sensor Status | 4 - 20 mA | |||||||||||||||
Min. measured value | 4 mA | |||||||||||||||
Max. measured value | 20 mA | |||||||||||||||
Underrange | 3,8 mA | |||||||||||||||
Overrange | 20,5 mA | |||||||||||||||
Plug-in transmitter - Accuracy and stability | ||||||||||||||||
Cold junction compensation | ||||||||||||||||
Cold Junction Compensation | ±0,3 – 0,5 °C (NTC 5K) | |||||||||||||||
Temperature influence | ±0,01 °C per °C | |||||||||||||||
Influence of the sensor cable | ||||||||||||||||
RTD and resistance (2-wire) | Negligible | |||||||||||||||
Further data | ||||||||||||||||
Supply voltage influence | Within specified limits | |||||||||||||||
Plug-in transmitter - Type | ||||||||||||||||
Dimensions (mm) | 84 x 60 x 34 (see drawing) | |||||||||||||||
Material | Flammability | ABS white RAL 9010 UV resistant, RoHS compliant | |||||||||||||||
Mounting | Enclosed mounting kit (housing) | |||||||||||||||
Connection | Single wires, max. 1,5 mm², AWG 16 | |||||||||||||||
Weight (g) | 75 | All dimensions in mm | ||||||||||||||
Plug-in transmitter - Protection sleeve | ||||||||||||||||
Material | Stainless steel 1.4404 | 316L | |||||||||||||||
Diameter (mm) | 6 | |||||||||||||||
Mounting length (mm) | 50 | |||||||||||||||
Plug-in transmitter - General data | ||||||||||||||||
Isolation | none | |||||||||||||||
Supply Voltage (VDC) | 12 to 36, polarity protected | |||||||||||||||
Plug-in transmitter - Ambient conditions | ||||||||||||||||
Ambient Temperatur | Storage: -20 °C to +70 °C (housing) | Operating: -20 °C to +70 °C (housing) | |||||||||||||||
Humidity (%rH) | 0 to 98 (non-condensing) | |||||||||||||||
Protection | Housing IP65 | |||||||||||||||
Plug-in transmitter - EMC | ||||||||||||||||
Standard | Directive: 2014/30/EU | Harmonized standards: EN 61326-1:2013 | |||||||||||||||
Plug-in transmitter - Factory configuration | ||||||||||||||||
Input | Pt1000 fixed | |||||||||||||||
Scaling | 0 °C to +100 °C | |||||||||||||||
Output | 4 to 20 mA | |||||||||||||||
Plug-in transmitter - Mounting | ||||||||||||||||
Open the rotary cover. | ||||||||||||||||
You can parameterize the output via the DIP switches. Important: To prevent measuring errors, the connecting screws for fastening the connecting cable must be tightened. | ||||||||||||||||
Mounting by using an immersion sleeve | ||||||||||||||||
Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve. Please make sure that you have sufficient space so that you can remove the probe again if necessary. | ||||||||||||||||
Mounting by using an immersion sleeve (4): Please make sure that the Ø and the length of the immersion sleeve are chosen according to the installation situation, so that the minimum immersion depth can be reached. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal conduction paste can improve the response times. | ||||||||||||||||
Mounting in the duct by means of mounting flange | ||||||||||||||||
Mounting by means of mounting flange: Please make sure that the Ø of the mounting flange matches the Ø of the protection sleeve. Suitable flanges can be found at testo-sensor.store. |
Type: | Einsteck-Transmitter |
Output: | 4-20 mA |
Input: | Pt1000 |
- Download Datenblatt Einsteck-Transmitter Basic 4-20 mA
- Download Bedienungsanleitung Einsteck-Transmitter Basic 4-20 mA
- Download Konformitätserklärung Einsteck-Transmitter Basic 4-20 mA
- Download Data sheet Plug-in transmitter Basic 4-20 mA
- Download Instruction manual Plug-in transmitter Basic 4-20 mA
- Download Betriebsanleitung Einsteck-Transmitter Basic 4-20 mA