Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.


Mounting length: | ||
Quantity: |
- Order number: 807004-0013
Advantages
- We are ready to deliver: All information here
- Advice directly from experts
- Quality directly from the manufacturer
- Long-term stable temperature probes over years
- B2B customers welcome: All information here

Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
The precise Pt1000 screw-in transmitter reliably measures temperatures in pipes and vessels. With the screw-in thread you can insert it safely and easily into the process. It is connected via an M12 connector. The output provides a standardized 0-10 mA output signal. This allows measured values to be transmitted error-free even over long distances. You can select the length of the protection sleeve. Accessories such as immersion sleeves, compression fittings and connection cables are available in our online store.
Here you can find our downloads for Screw-in transmitter G1/2 " M12 connector 0-10 V
Screw-in transmitter - Special features | ||||||||||||||||
Inputs and outputs | Input: Pt1000 resistance sensor, permanently installed Output: 0 to 10 V | |||||||||||||||
Accuracy & Long-term stability | Accuracy: high measuring accuracy Long-term stability: long service life with flexible application possibilities | |||||||||||||||
Design | compact, robust, vibration and shock resistant design | |||||||||||||||
Parametrization | pressure resistant up to screw cap insertion in the process | |||||||||||||||
Alarm function | Sensor break monitoring Sensor short-circuit monitoring Measuring range monitoring | |||||||||||||||
Screw-in transmitter - Measuring element | ||||||||||||||||
Measuring element | Norm | Configurable measuring range | Accuracy | |||||||||||||
Pt1000 | IEC 60751 | -200 °C to +850 °C | -328 °F to +1562 °F | ±0.5 °C - 1 °C over the entire measuring range | |||||||||||||
Connection type | 2-wire (permanently installed) | |||||||||||||||
Screw-in transmitter - Output | ||||||||||||||||
Output type | analog, temperature linear for RTD | |||||||||||||||
Output signal | 0 to 10 V | |||||||||||||||
Parametrization / Scaling | Configurable via DIP-Switch | |||||||||||||||
Resolution | 16 bit dac | |||||||||||||||
Measurment accuracy (°C) | 0,1 | |||||||||||||||
Load | 500 Ω at 24 VDC | |||||||||||||||
Connection type | 2-wire and 3-wire | |||||||||||||||
Screw-in transmitter - Time response | ||||||||||||||||
Closing time | ~150 - 300 | |||||||||||||||
Heating period | The specified accuracy is reached after max. 4 minutes | |||||||||||||||
Signal attenuation | 0 – 30 | |||||||||||||||
Measuring cycle (s) | <0,25 ( < 4 Hz ) | |||||||||||||||
Response time | Depending on sensor type | |||||||||||||||
Screw-in transmitter - Sensor monitoring & sensor error | ||||||||||||||||
Sensor failure effects | according to NAMUR NE43 | |||||||||||||||
Screw-in transmitter - Alarms | ||||||||||||||||
Sensor error | 0 - 10 V | |||||||||||||||
Sensor Status | 11 V | |||||||||||||||
Sensor short circuit | 11 V | |||||||||||||||
Screw-in transmitter - Measured values outside the measuring range | ||||||||||||||||
Sensor Status | 0 - 10 V | |||||||||||||||
Min. measured value | 0,5 V | |||||||||||||||
Max. measured value | 10 V | |||||||||||||||
Underrange | 0 V | |||||||||||||||
Overrange | 10,5 V | |||||||||||||||
Screw-in transmitter - Accuracy and stability | ||||||||||||||||
Cold junction compensation | ||||||||||||||||
Cold Junction Compensation | ±0,3 – 0,5 °C (NTC 5K) | |||||||||||||||
Temperature influence | ±0,01 °C per °C | |||||||||||||||
Influence of the sensor cable | ||||||||||||||||
RTD and resistance (2-wire) | Negligible | |||||||||||||||
Further data | ||||||||||||||||
Supply voltage influence | Within specified limits | |||||||||||||||
Screw-in transmitter - Type | ||||||||||||||||
Dimensions (mm) | See drawing | ![]() | ||||||||||||||
Material | Flammability | Stainless steel 1.4404 | 316L | |||||||||||||||
Mounting | via process connection | |||||||||||||||
Connection | M12 | |||||||||||||||
Weight (g) | 0 | All dimensions in mm | ||||||||||||||
Screw-in transmitter - Protection sleeve | ||||||||||||||||
Material | Stainless steel 1.4404 | 316L | |||||||||||||||
Diameter (mm) | 6 | |||||||||||||||
Mounting length (mm) | 50 | |||||||||||||||
Screw-in transmitter - General data | ||||||||||||||||
Isolation | none | |||||||||||||||
Supply Voltage (VDC) | 12 to 36, polarity protected | |||||||||||||||
Screw-in transmitter - Ambient conditions | ||||||||||||||||
Ambient Temperatur | Storage: -30 °C to +70 °C | -22 °F to +158 °C | Operating: -50 °C to +150 °C | -58 °F to +302 °F | |||||||||||||||
Humidity | 0 to 98 (non-condensing) | |||||||||||||||
Protection | IP65 | |||||||||||||||
Screw-in transmitter - EMC | ||||||||||||||||
Standard | Directive: 2014/30/EU | Harmonized standards: EN 61326-1:2013 | |||||||||||||||
Screw-in transmitter - Factory configuration | ||||||||||||||||
Input | Pt1000 fixed | |||||||||||||||
Scaling | 0 °C to +100 °C | |||||||||||||||
Output | 0 - 10 V | |||||||||||||||
Screw-in transmitter - Mounting | ||||||||||||||||
Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve. Please make sure that you have sufficient space so that you can remove the probe again if necessary. | ![]() | |||||||||||||||
Mounting by using an immersion sleeve (4): Please make sure that the Ø and the length of the immersion sleeve are chosen according to the installation situation, so that the minimum immersion depth can be reached. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal conduction paste can improve the response times. | ![]() |
Type: | Einschraub-Transmitter |
Output: | 0-10V |
Input: | Pt1000 |
- Download Datenblatt Einschraub-Transmitter G1/2 " M12 Stecker 0-10 V
- Download Bedienungsanleitung Einschraub-Transmitter G1/2 " M12 Stecker 0-10 V
- Download Konformitätserklärung Einschraub-Transmitter G1/2 " M12 Stecker 0-10 V
- Download Data sheet Screw-in transmitter G1/2 " M12 connector 0-10 V
- Download Instruction manual Screw-in transmitter G1/2 " M12 connector 0-10 V
- Download Betriebsanleitung Einschraub-Transmitter G1/2 " M12 Stecker 0-10 V
Testo Sensor GmbH