Quality directly from the manufacturer
Long-term stable temperature probes over years
Advice directly from experts
 

Cable thermocouple type J with glass fibre cable

€15.62 *

Prices incl. VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 4 Workdays to GER (AT, NL, BE +1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configuration
C - Length protection sleeve

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

keine Auswahl
(C0030) 30 mm
(C0040) 40 mm
(C0050) 50 mm
(C0060) 60 mm
(C0100) 100 mm
(C0200) 200 mm
D - Diameter protection sleeve

Bei Temperaturmessungen in Festkörpern oder wenn der Fühler in einer Tauchhülse montiert ist, verlangsamt die den Fühler umgebende Luft die Wärmeleitung vom Medium zum Fühler. Dadurch wird auch die Temperaturmessung verlangsamt und führt im Extremfall zu falschen Temperaturmesswerten. Achten Sie bitte deshalb darauf, dass der Temperaturfühler wärmetechnisch bestmöglich an Ihr Messmedium angekoppelt ist, d.h. wählen Sie den Hülsendurchmesser so aus, dass der Luftspalt so klein wie möglich wird.

(D040) Ø 4,0 mm
(D050) Ø 5,0 mm
(D060) Ø 6,0 mm
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
Glasseide: -50 °C bis +400 °C

(E8310) GLS/VA (2 x 0,22 mm²)
F - Length connection cable
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector

Bitte beachten Sie den spezifizierten Temperaturbereich des Stecker / der Aderendenhülsen
isolierte Aderendhülsen: bis 80 °C
Mini-TE-Stecker: bis 220 °C
TE-Stecker: bis 220 °C

(G01) isolierte Aderendhülsen
(G11) Mini-TC connector J bk
(G31) TC connector J bk
H - Bend protection
(H0) Without (Standard)
Image Changer
2.How many probes do you need?
Price calculation
Basic price
€15.62
C - Length protection sleeve:  
D - Diameter protection sleeve:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Quantity:  
Configuration is incomplete - please check it!
  • 803580-1111
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

  • Advice directly from experts
  • Quality directly from the manufacturer
  • Long-term stable temperature probes over years
  • B2B customers welcome: All information here
Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Cable thermocouples with with glass fibre cables are shielded and measure the temperature up to... more
Product information "Cable thermocouple type J with glass fibre cable"

Cable thermocouples with with glass fibre cables are shielded and measure the temperature up to +400 °C. They are crimped and also have poorer sealing than other cables due to the insulation material used.

Here you can find our downloads for the Cable thermocouple Type J with glass fibre cable

pdf-download Data sheet Cable thermocouple Type J with glass fibre cable
pdf-download Instruction manual Cable thermocouple Type J with glass fibre cable
pdf-download Operating instruction Cable thermocouple Type J with glass fibre cable
pdf-download Declaration of Conformity Cable thermocouple Type J with glass fibre cable
step-download Step files Cable thermocouple Type J with glass fibre cable
 

Cable thermocouple - General Information

Measuring range -40 °C to +400 °C depending on chosen connection cable
Perm. °C range cable -50 °C to +400 °C
Accuracy -40 °C to +375 °C: ±1,5 °C | 375 °C to 750 °C: ±0,004 |t| according to DIN IEC 60584 Class 1
Response time on request
Pull-out force ≥ 30 N
                                       

Cable thermocouple - Supply and output

Measuring element Thermocouple Type J
Measuring point Measuring point isolated
Measurement signal Thermovoltage
 

Cable thermocouple - Ambient conditions

Protection class IP20 according DIN 60529 (depending on cable)
Humidity and moisture condensation resistance according to application-specific qualification
 

Cable thermocouple - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
 

Cable thermocouple - Technical Drawing

C - Length protection sleeve
D - Diameter protection sleeve
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Cable thermocouple - Protection sleeve

Diameter (mm)1} 4, 5, 6
Length (mm)2} 30, 40, 50, 60, 100, 200
1} Tolerance ± 0,1 mm | 2} Tolerance length ≤ 100: ± 1 mm / length > 100: ± 1 %
 

Cable thermocouple - Material and possible configuration

Length / Ø (mm) 3 4 5 6
30 not available Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
40 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
50 not available Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
60 not available not available not available Stainless steel 1.4571 | 316TI
100 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI
200 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI
other protective sleeve lengths and Ø available on request
 

Cable thermocouple - Thermocouple cable

Type Color Material (Outside / Inside) Perm. range °C Ø Outside (mm) Cross section (mm²) Color strand Ω / m
Thermocouple cable Type J1} Glass fibre / Varnish -50 to +400 3,0 ± 0,2 0,22  bk, wt 2,502}
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | 1}Color according to IEC 584 | 2}per thermocouple | Cable available as accessory
 

Cable thermocouple - Connector

Insulated end ferrules (50 mm)
Mini-TC connector Type J bk
TC connector Type J bk
 

Cable thermocouple - Delivery

Assembly instructions by using compression fitting or immersion sleeve
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Immersion sleeve, Heat-conducting paste, Compression fitting, Thermocouple cable, Connectors, Couplings, Quick-release strap
 

Cable thermocouple - Important assembly advices

Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve or, when using an immersion sleeve, the Ø of the immersion sleeve. When installing in pipelines whose Ø does not have a sufficiently deep installation depth, you should install the probe either at an angle or in a pipe elbow. Make sure that there is sufficient space for the probe to be removed. 1) Installation with sufficient installation depth 2) Installation at an angle with small pipe Ø 3) Not like this: Minimum installation depth not reached

Installation by means of compression fitting: Please tighten the union nut of the compression fitting by hand as far as it will go (clearly noticeable). For compression fittings with PTFE pressure ring, please make a 1/4 turn with a wrench suitable for the width across flats. These compression fittings can be used several times in this way. In the case of compression fittings with stainless steel cutting ring, the compression fitting connects to the protection tube. This connection is pressure resistant up to 40 bar. However, the compression fitting can only be used once. It must also be tightened more firmly. Please tighten it with 1 3/4 turns.

Mounting by using an immersion sleeve (4): Please note that the Ø and the length of the immersion sleeve must be selected to suit the installation situation so that the minimum immersion depth can be achieved. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal paste can improve the response times.

Please lay the cable with reserve loop (4) and in such a way that no water can penetrate the sensor head. This allows you to extend the probe without disconnecting the electrical connection.

Properties
Thermocouple: Type J Class 1
Temperature range: -40 °C to +400 °C
Material cable: Glass fibre
industry: Air conditioning and ventilation technology, Automotive, Building automation, Food industry, Heating technology, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Refrigeration, White goods
Related links to "Cable thermocouple type J with glass fibre cable"
Available downloads:
Read, write and discuss reviews... more
Customer evaluation for "Cable thermocouple type J with glass fibre cable"
Write an evaluation
Each consumer review is checked for authenticity before it is published, ensuring that reviews only come from consumers who have actually purchased/used the products being reviewed. The verification is carried out by manual checking in the form of a comparison of the rating with the order history of the merchandise management system in order to make a previous product purchase a necessary condition for publication.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Kabel-Thermoelement Typ J mit PVC-Leitung Vorderansicht Cable thermocouple type J with PVC cable
€9.38 *
Order number: 803550-1111
Add to shopping cart
Kabel-Thermoelement Typ J mit Silikon-Leitung Vorderansicht Cable thermocouple type J with silicone cable
€11.04 *
Order number: 803560-1111
Add to shopping cart
Kabel-Thermoelement Typ J mit PFA-Leitung Vorderansicht Cable thermocouple type J with PFA cable
€14.79 *
Order number: 803570-1111
Add to shopping cart
Kabel-Thermoelement Typ K mit Glasseide-Leitung Vorderansicht Cable thermocouple type K with glass fibre cable
€15.62 *
Order number: 803580-1211
Add to shopping cart
Hutschienen-Transmitter + Kabel-Thermoelement Typ J Glasseide - Vorderansicht Hat rail transmitter + cable thermocouple type...
€85.72 *
Order number: 803580-1191
Add to shopping cart
Kabelfühler mit Glasseide-Leitung Vorderansicht Cable probe with glass fibre cable
€14.24 *
Order number: 803580-1011
Add to shopping cart