The pressure transmitter housing with display bottom enables precise measurement of differential pressure and displays the current measured values clearly at all times. Eight switchable measuring ranges and two output signals (0-10 V or 4-20 mA) ensure maximum flexibility. The compact housing with bottom connections and practical snap-on cover can be mounted quickly and easily. The IP54 protection rating offers solid protection for use in ventilation and air conditioning systems, clean rooms, or for filter monitoring. A manual zero point adjustment rounds off the functions.
Here you can find our downloads for Pressure transmitter housing with display bottom
Pressure transmitter - Supply and output | ||||||||||||||||
| Output | 0 - 10 V or 4 - 20 mA (via DIP switch) | |||||||||||||||
| Load resistance | Rl > 25 kOhm for voltage output | |||||||||||||||
| Load | Ra (Ohm) = 25 Ohm to 450 Ohm for current output | |||||||||||||||
| Signal filtering | Switchable 1 s / 10 s (via DIP switch) | |||||||||||||||
| Power consumption | < 1 W / 24 V DC; < 2 VA / 24 V AC | |||||||||||||||
| Power input | < 45 mA | |||||||||||||||
| Voltage supply | 24 V AC / DC (± 10 %) | |||||||||||||||
Pressure transmitter - Pressure | ||||||||||||||||
| Pressure type | Differential pressure | |||||||||||||||
| Measuring function | Differential pressure, volume flow (square root output signal) | |||||||||||||||
| Pressure range selectable | max. ± 100 Pa max. ± 1000 Pa max. ± 5000 Pa | |||||||||||||||
| Measuring range | multi-range switching with 8 switchable measuring ranges | |||||||||||||||
| Accuracy pressure | typically ± 3 Pa (at ±100 Pa), ± 10 Pa (at ±1000 Pa), ± 35 Pa (at ±5000 Pa) at +25 °C | |||||||||||||||
| Zero offset | ± 10 % Measuring range | |||||||||||||||
| Linearity | < ± 1 % EW | |||||||||||||||
| Hysteresis | 0,3 % EW | |||||||||||||||
| Overpressure / underpressure | ± 50 kPa | |||||||||||||||
Pressure transmitter - Ambient conditions | ||||||||||||||||
| Storage temperature | -30 °C to +80 °C | |||||||||||||||
| Operating temperature | -20 °C to +50 °C | |||||||||||||||
| Permissible air humidity | < 95 % r. H., non-precipitating air< 95 % RH, non-condensing air | |||||||||||||||
| Medium temperature | -20 °C to +50 °C (temperature compensated 0 °C to 50 °C) | |||||||||||||||
| Medium | clean air and non-aggressive, non-flammable gases | |||||||||||||||
| Temperature drift | ± 0.1 % per °C EW | |||||||||||||||
| Long-term stability | ± 1 % / year | |||||||||||||||
Pressure transmitter - Certifications / Standards | ||||||||||||||||
| Protection class | III (according to EN 60 730) | |||||||||||||||
| Protection type | IP 54 according to EN 60 529 | |||||||||||||||
| Standards | CE conformity according to EMC Directive 2014/ 30/ EU | |||||||||||||||
Pressure transmitter - Technical drawing | ||||||||||||||||
![]() | ||||||||||||||||
Pressure transmitter - Housing | ||||||||||||||||
| Material | Plastic, UV-resistant Material polyamide, 30 % glass bead reinforced | |||||||||||||||
| Dimensions (L/W/H) (mm) | 72 x 64 x 43,3 | |||||||||||||||
| Color | Traffic white (similar to RAL9016) | |||||||||||||||
| Wetted parts | Brass, Ni, thermoset, Si, epoxy, RTV, BSG, UV silicone gel | |||||||||||||||
| Electrical connection | 0.14 - 1.5², via screw terminals on circuit board | |||||||||||||||
| Display | Two lines, lighted For display of actual pressure | |||||||||||||||
| Cut-out Display (B/H) (mm) | ca. 36 x 15 | |||||||||||||||
| Extra | For display of actual pressure | |||||||||||||||
| Closure | with snap cap | |||||||||||||||
| Pressure connection | with connection piece for pressure hose ⌀ 6 mm | |||||||||||||||
| Electrical connection | 0.14 - 1.5 mm², via screw terminals on circuit board | |||||||||||||||
| Screw connection | Cable gland, Plastic, M20x1,5, Strain relief, replaceable, max. 10,4 mm ⌀ Inner | |||||||||||||||
Pressure transmitter - Important assembly instructions | ||||||||||||||||
![]() | ||||||||||||||||
| [A] Negative pressure P1 (+) is not connected, is open to the atmosphere on the air side P2 (-) connection in the duct [B] Filter: P1 (+) connection before the filter P2 (-) connection after the filter [C] Fan: P1 (+) connection before the fan P2 (-) connection after the fan [D] Volume flow: P1 (+) dynamic pressure, connection in flow direction P2 (-) static pressure, connection free of dynamic V = k · √Δ p (V = volume flow | k = k-factor | Δ p = differential pressure [Pa]) | ||||||||||||||||
| The device is supplied with the connection set (hoses and connection nipples). The pressure connections must be connected correctly according to the required monitoring type (see diagram). Before commissioning, check the pressure lines and electrical wiring for leaks. | ||||||||||||||||
Pressure transmitter - Delivery | ||||||||||||||||
| Delivery | Transmitter, Operating instructions | |||||||||||||||
| Packing | individually packed in cardboard box | |||||||||||||||
| Output: | 0-10 V, 4-20 mA |
| Gehäuse: | Housing with display |
| Schutzart: | IP 54 acc. EN 60 529 |
| Messgröße: | Differential pressure |
| Type: | Differential pressure transmitter |
- Download Datenblatt Druckmessumformer Gehäuse mit Display Unten
- Download Datasheet Pressure transmitter housing with display bottom
- Download Bedienungsanleitung Druckmessumformer Gehäuse mit Display Unten
- Download Konformitätserklärung Druckmessumformer Gehäuse mit Display Unten
- Download Datenblatt Druckmessumformer Gehäuse mit Display Unten
- Download Datasheet Pressure transmitter housing with display bottom
- Download Bedienungsanleitung Druckmessumformer Gehäuse mit Display Unten
- Download Konformitätserklärung Druckmessumformer Gehäuse mit Display Unten
S+S Regeltechnik GmbH
Thurn-und-Taxis-Str. 22
90411 Nürnberg
E-Mail mail[at]SplusS.de