1.Configure and order now
A - Measuring element

Bitte prüfen Sie, welches Messelement (Thermistortyp oder Pt) für Ihre Anwendung der Passende ist. Wichtige Informationen zum Messelement entnehmen Sie bitte den Kennlinien und Datenblättern. Diese finden Sie in der Langbeschreibung oder in unserem Download-Bereich.

keine Auswahl
(A011) Pt100 Class A
(A012) Pt100 Class B
(A013) Pt100 1/3 Class B
(A014) Pt100 1/10 Class B
(A022) Pt500 Class B
(A031) Pt1000 Class A
(A032) Pt1000 Class B
(A105) NTC 5 kOhm
(A110) NTC 10 kOhm
(A120) NTC 20 kOhm
(A210) Ni1000
(A421) KTY 81-210
(A411) KTY 81-110
(A520) DS18B20
(A323) LM235Z
B - Connection Type

Bei Zwei-Leiter-Schaltungen addiert sich der Eigenwiderstand der Anschlussleitung zum Widerstandswert des Messwiderstands (Thermistor oder Pt) und verfälscht somit das Messergebnis. Ist der Widerstandswert des Messwiderstands groß gegenüber dem Eigenwiderstand der Anschlussleitung, so kann dieser Eigenwiderstand vernachlässigt werden. Bei Messwiderständen mit geringerem Widerstandswert (z.B. PT100), kann der Leitungseigenwiderstand die Messgenauigkeit jedoch signifikant verringern. Aus diesem Grund empfehlen wir die Zwei-Leiter-Technik in Verbindung mit kleinohmigen Messwiderständen nur dann, wenn Sie vergleichsweise kurze Anschlussleitungen, also kleinohmige Anschlussleitungen, verwenden können.

Für Applikationen, die eine sehr genaue Temperaturmessung erfordern, empfehlen wir Ihnen eine Drei- oder sogar Vier-Leiterschaltung zu verwenden.

Bei der Dreileiter-Schaltung wird der Leitungswiderstand jeder der drei angeschlossenen Leitungen mit Hilfe der dritten angeschlossenen Leitung ermittelt (alle Anschlussdrähte müssen exakt gleich lang sein) und anschließend vom gemessenen Gesamtwiderstand (Messwiderstand+Leitungswiderstand) abgezogen werden, so dass effektiv nur der Widerstandswert des Messwiderstands für die Temperaturbestimmung verwendet wird. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

Die sicherste und genaueste Messung erreichen Sie mit Hilfe einer Vierleiter-Schaltung. Hier wird auf jeder Seite des Messwiderstands eine zusätzliche Leitung angeschlossen. Zwei Leitungen dienen der Spannungsversorgung, die zwei anderen werden verwendet, um den Leitungswiderstand (ggf. auch asymmetrisch, also auch bei unterschiedlich langen Anschlussdrähtchen) zu ermitteln und vom Messwiderstandswert abzuziehen. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

(B2) 2-Wire
(B3) 3-Wire
(B4) 4-Wire
(B3) 3-Wire
C - Mounting length

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

(C0050) 50 mm
(C0100) 100 mm
(C0150) 150 mm
(C0200) 200 mm
(C0250) 250 mm
(C0300) 300 mm
(C0400) 400 mm
(C0500) 500 mm
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Sie haben die gewünschte Kalibrierung nicht gefunden? Schreiben Sie uns gerne an webshop@testo-sensor.de. 

Sie haben weitere Fragen oder möchten herausfinden, welche Kalibrierung die richtige für Ihren Temperaturfühler ist - dafür haben wir alle Informationen auf dieser Seite für Sie zusammengefasst. Temperaturfühler kalibrieren

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration
1-Point measurement (0 °C)
1-Point measurement (60 °C)
2-Point measurement (0 °C, 60 °C)
3-Point measurement (-18 °C, 0 °C, 60 °C)
DAkkS-Calibration
3-Point measurement (-20 °C, 0 °C, 60 °C)
3.How many probes do you need?
Price calculation
Basic price
27,27 €
A - Measuring element:  
B - Connection Type:  
C - Mounting length:  
Calibration:  
ISO-Calibration:  
DAkkS-Calibration:  
Quantity:  
Configuration is incomplete - please check it!
  • 803710-2011
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Our duct probe with aluminum flange is used to measure the temperature in gaseous media in a...more
Product information "Duct probe with housing and aluminium flange"

Our duct probe with aluminum flange is used to measure the temperature in gaseous media in a temperature range of -30 °C up to +150 °C. For an easy and quick mounting, a suitable aluminum flange is included. Further mounting flanges made of stainless steel or plastic can be found in our accessories.

Here you can find our downloads for the Duct probe with housing and aluminium flange

pdf-download Data sheet Duct probe with housing and aluminium flange
pdf-download Instruction manual Duct probe with housing and aluminium flange
pdf-download Operating instruction Duct probe with housing and aluminium flange
pdf-download Declaration of Conformity Duct probe with housing and aluminium flange
 

Duct probe - General Information

Measuring range -30 °C to +150 °C depending on the sensor type
Perm. temperature range housing -30 °C to +90 °C
Accuracy depending on sensor type
Response time t63 / t99: information is available on request
                                       

Duct probe - Supply and output

Max. measurement current max. 1 mA
Supply voltage approx. 5 V depending on measurement current
Measurement signal passive (resistance value)
 

Duct probe - Ambient conditions

Protection class IP65 according DIN 60529 
Humidity and moisture condensation resistance according to application-specific qualification
 

Duct probe - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Duct probe - Technical Drawing

A - Measuring element
B - Connection type
C - Mounting length
All dimensions in mm
 

Duct probe - Measuring element

Measuring element Perm. range °C Accuracy / Tolerance resistance
Pt100 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt100 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Pt100 -50 °C to +200 °C 1/3 Class B dT = ±(1/3 · (0,30 °C + 0,005|t|))1}
Pt100 ±0 °C to +100 °C 1/10 Class B dT = ±(1/10 · (0,30 °C + 0,005|t|))1}
Pt500 -70 °C to +500 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
NTC 5 kOhm -40 °C to +125 °C R25 = 5 KOhm ±1 %
NTC 10 kOhm -40 °C to +125 °C R25 = 10 KOhm ±1 %
NTC 20 kOhm -40 °C to +125 °C R25 = 20 KOhm ±1 %
KTY 81-210 -50 °C to +150 °C R25 = 2 KOhm ±1 %
KTY 81-110 -50 °C to +150 °C R25 = 1 KOhm ±1 %
DS18B20 -55 °C to +125 °C -10 °C to +85 °C: ±0,5 °C | -30 °C to +100 °C: ±1 °C | -55 °C to +125 °C: ±2 °C
LM235Z -40 °C to +125 °C typical ±1 °C
Ni1000 -60 °C to +150 °C -60 °C to 0 °C: dT = ±(0,4 °C + 0,028 · T) | 0 °C to +150 °C: dT = ±(0,4 °C + 0,007 · T)
1} according to IEC 751 / EN 60751
 

Duct probe - Possible connections

Measuring element 2W 3W 4W
NTC Checkmark    
KTY Checkmark    
LM235Z Checkmark    
DS18B20   Checkmark  
NI Checkmark Checkmark Checkmark
Pt Checkmark Checkmark Checkmark
 

Duct probe - Protection sleeve

Material Stainless steel 1.4571 | 316TI
Diameter (mm)1} 6
Mounting length (mm)2} 50, 100, 150, 200, 250, 300, 400, 500
1} Tolerance ± 0,1 mm | 2} Tolerance ± 1%
 

Duct probe - Housing

Material Polyamide
Dimension (L/W/H) (mm) 64 x 58 x 35
Color white similar RAL 9010
Cable entry with strain relief
Clamping range (mm) 5 to 9
Electrical connection Screw terminals max. 1,5 mm²
 

Duct probe - Flange

Material Aluminum
Hole (mm) 6
Fixing two holes Ø 4.5 mm
 

Duct probe - Delivery

Assembly instructions Installation by using the enclosed mounting flange
Delivery and Packaging Probe, Mounting flange, seperatly packaged in PE bag
Matching accessories Compression fitting, Mounting flange, Cable
 

Duct probe - Important assembly advices

Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve. Please make sure that you have enough space to remove the probe if necessary.

Mounting by means of compression fitting: Please tighten the union nut of the compression fitting by hand until it stops (clearly noticeable). With a wrench suitable for the wrench size, please make a 1/4 turn for compression fittings with PTFE pressure ring. These compression fittings can be used several times in this way. In the case of compression fittings with stainless steel cutting ring, the compression fitting connects to the protection tube. This connection is pressure resistant up to 40 bar. However, the compression fitting can only be used once. It must also be tightened more firmly. Please tighten it with 1 3/4 turns.

Mounting by means of mounting flange (included in delivery): Please make sure that the Ø of the mounting flange matches the Ø of the protection sleeve.

Please lay the cable with reserve loop (5) and in such a way that no water can penetrate into the sensor head. This allows you to extend the probe without disconnecting the electrical connection.

 

Qualification measurement series to ensure the function of our temperature probes over their service life

Qualifizierungsmessreihe Robust even with temperature changes Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. Checkmark
Qualifizierungsmessreihe Resistant to heat and humidity Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified.        
Qualifizierungsmessreihe Long-term stable in any weather Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification.        
Qualifizierungsmessreihe Robust even under high vibration load Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g).        
Qualifizierungsmessreihe Reliable in practice: high pull-out force The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. Checkmark
Qualifizierungsmessreihe Efficient through short response time Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. Checkmark
Qualifizierungsmessreihe Corrosion-resistant even in salt spray Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years.        
Checkmark

Applicable for this probe type

Properties
Measuring element: DS18B20, KTY 81-110, KTY 81-210, LM235Z, Ni1000, NTC 5 kOhm, NTC 10 kOhm, NTC 20 kOhm, Pt100 1/3 Class B, Pt100 1/10 Class B, Pt100 Class A, Pt100 Class B, Pt500 Class B, Pt1000 Class A, Pt1000 Class B
Temperature range: -30 °C to +150 °C
Connection type: 2-Wire, 3-Wire, 4-Wire
industry: Air conditioning and ventilation technology, Building automation, Refrigeration
Related links to "Duct probe with housing and aluminium flange"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Duct probe with housing and aluminium flange"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Kanalfühler mit Gehäuse und Kunststoffflansch Vorderansicht Duct probe with housing and plastic flange
26,77 € *
Order number: 803710-1011
Add to shopping cart
Mittelwertfühler Vorderansicht Average value probe
88,23 € *
Order number: 803712-1011
Add to shopping cart
Kanalfühler mit J-Kopf und Aluminiumflansch Vorderansicht Duct probe with J-Head and aluminium flange
39,11 € *
Order number: 803711-2011
Add to shopping cart