Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Contact probe with ring and glass fibre cable

€ 41,08 *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to NL, BE, AT (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
A - Measuring element

Bitte prüfen Sie, welches Messelement (Thermistortyp oder Pt) für Ihre Anwendung der Passende ist. Wichtige Informationen zum Messelement entnehmen Sie bitte den Kennlinien und Datenblättern. Diese finden Sie in der Langbeschreibung oder in unserem Download-Bereich.

keine Auswahl
(A011) Pt100 Class A
(A012) Pt100 Class B
(A022) Pt500 Class B
(A031) Pt1000 Class A
(A032) Pt1000 Class B
B - Connection Type

Bei Zwei-Leiter-Schaltungen addiert sich der Eigenwiderstand der Anschlussleitung zum Widerstandswert des Messwiderstands (Thermistor oder Pt) und verfälscht somit das Messergebnis. Ist der Widerstandswert des Messwiderstands groß gegenüber dem Eigenwiderstand der Anschlussleitung, so kann dieser Eigenwiderstand vernachlässigt werden. Bei Messwiderständen mit geringerem Widerstandswert (z.B. PT100), kann der Leitungseigenwiderstand die Messgenauigkeit jedoch signifikant verringern. Aus diesem Grund empfehlen wir die Zwei-Leiter-Technik in Verbindung mit kleinohmigen Messwiderständen nur dann, wenn Sie vergleichsweise kurze Anschlussleitungen, also kleinohmige Anschlussleitungen, verwenden können.

Für Applikationen, die eine sehr genaue Temperaturmessung erfordern, empfehlen wir Ihnen eine Drei- oder sogar Vier-Leiterschaltung zu verwenden.

Bei der Dreileiter-Schaltung wird der Leitungswiderstand jeder der drei angeschlossenen Leitungen mit Hilfe der dritten angeschlossenen Leitung ermittelt (alle Anschlussdrähte müssen exakt gleich lang sein) und anschließend vom gemessenen Gesamtwiderstand (Messwiderstand+Leitungswiderstand) abgezogen werden, so dass effektiv nur der Widerstandswert des Messwiderstands für die Temperaturbestimmung verwendet wird. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

Die sicherste und genaueste Messung erreichen Sie mit Hilfe einer Vierleiter-Schaltung. Hier wird auf jeder Seite des Messwiderstands eine zusätzliche Leitung angeschlossen. Zwei Leitungen dienen der Spannungsversorgung, die zwei anderen werden verwendet, um den Leitungswiderstand (ggf. auch asymmetrisch, also auch bei unterschiedlich langen Anschlussdrähtchen) zu ermitteln und vom Messwiderstandswert abzuziehen. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

(B2) 2-Wire
(B3) 3-Wire
(B4) 4-Wire
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
Glasseide: -50 °C bis +400 °C

(E3300) GLS/VA (2 x 0,22 mm²)
(E3301) GLS/VA (3 x 0,22 mm²)
(E3302) GLS/VA (4 x 0,22 mm²)
F - Length connection cable

Bei sehr langen Anschlussleitungen beachten Sie bitte den Einfluss des Eigenwiderstandswerts der Leitung auf die Messgenauigkeit. Für Fühler mit Pt-oder Ni-Messelementen empfehlen wir in diesem Fall den Einsatz einer Drei- oder Vierleiterschaltung.

(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector
(G01) Insulated end ferrules
(G01) Insulated end ferrules
(G01) Insulated end ferrules
H - Bend protection
(H0) Without (Standard)
Image Changer
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Sie haben die gewünschte Kalibrierung nicht gefunden? Schreiben Sie uns gerne an webshop@testo-sensor.de. 

Sie haben weitere Fragen oder möchten herausfinden, welche Kalibrierung die richtige für Ihren Temperaturfühler ist - dafür haben wir alle Informationen auf dieser Seite für Sie zusammengefasst. Temperaturfühler kalibrieren

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration
1-Point measurement (60 °C)
1-Point measurement (120 °C)
3-Point measurement (60 °C, 120 °C, 180 °C)
DAkkS-Kalibrierung
3-Punkt Messung (100 °C, 200 °C, 300 °C)
3.How many probes do you need?
Price calculation
Basic price
€ 41,08
A - Measuring element:  
B - Connection Type:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Calibration:  
ISO-Calibration:  
DAkkS-Kalibrierung:  
Quantity:  
Configuration is incomplete - please check it!
  • 802082-1011
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Our contact probe with ring and glass fibre cable is used for temperature measurements on smooth...more
Product information "Contact probe with ring and glass fibre cable"

Our contact probe with ring and glass fibre cable is used for temperature measurements on smooth surfaces in machine and apparatus construction. It is attached via a screw connection and can be mounted directly onto the surface with the ring. Glass silk cables are crimped and have a poorer seal than other cable materials due to the insulation material used, but can be used in temperature ranges up to +400 °C.

Here you can find our downloads for the Contact probe with ring and glass fibre cable

pdf-download Data sheet Contact probe with ring and glass fibre cable
pdf-download Instruction manual Contact probe with ring and glass fibre cable
pdf-download Operating instruction Contact probe with ring and glass fibre cable
pdf-download Declaration of Conformity Contact probe with ring and glass fibre cable
 

Surface probe - General Information

Measuring range -50 °C to +400 °C depending on sensor Type and connection cable
Perm. °C range cable -50 °C to +400 °C
Accuracy a seconda dell´elemento sensibile
                                       

Surface probe - Supply and output

Max. measurement current max. 1 mA
Supply voltage approx. 5 V depending on measurement current
Measurement signal passive (resistance value)
 

Surface probe - Ambient conditions

Protection class IP20 according DIN 60529 (depending on cable)
Humidity and moisture condensation resistance according to application-specific qualification
 

Surface probe - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
 

Surface probe - Technical Drawing

A - Measuring element
B - Connection Type
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Surface probe - Measuring element

Measuring element Perm. range °C Accuracy / Tolerance resistance
Pt100 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt100 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Pt500 -70 °C to +500 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
1} according to IEC 751 / EN 60751 | Please note that the measuring range depends on the measuring element and the connecting cable.
 

Surface probe - Possible connections

Measuring element 2W 3W 4W
Pt Checkmark Checkmark Checkmark
 

Surface probe - Contact body

Contact geometry Ring
Material Brass
Height (mm) 6
Total length (mm) 36
Diameter (mm) 16
Mounting hole (mm) 6,8
 

Surface probe - Material connection cable

Color: steel, Perm. range °C: -50 to +400
Material (Outside / Inside) Ø Outside (mm) Cross section (mm²)2} Color strand Ω / m1}
Varnish 3,2 ± 0,2 2 x 0,22 rd, wt 0,09
Varnish 3,2 ± 0,2 3 x 0,22 rd, wt, rd 0,09
Varnish 3,4 ± 0,2 4 x 0,22 rd, wt, rd, wt 0,09
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm a min. 100 VDC | Cable available as accessory | 1} per single strand | 2} Tolerance ± 0,03 mm²
 

Surface probe - Connector

Insulated end ferrules (50 mm)
 

Surface probe - Delivery

Assembly instructions by means of screw fastening or mounting adhesive
Delivery and Packaging Probe, Heat-conducting paste, seperatly packaged in PE bag
Matching accessories Heat-conducting paste
 

Surface probe - Important assembly advices

The surface must be polished and free of residue. Please attach the probe firmly. Please ensure good thermal contact and use thermal conduction paste if necessary. Depending on the requirements, it may be advisable to insulate the probe to minimize the influence of the ambient temperature.

Properties
Kalibrierung: DAkkS-Kalibrierung, ISO-Kalibrierung
Measuring element: KTY 81-110, KTY 81-210, LM235Z, Ni1000, NTC 5 kOhm, NTC 10 kOhm, NTC 20 kOhm, Pt100 Class A, Pt100 Class B, Pt500 Class B, Pt1000 Class A, Pt1000 Class B
Temperature range: -30 °C to +105 °C
Connection type: 2-Wire, 3-Wire, 4-Wire
Material cable: PVC
industry: Air conditioning and ventilation technology, Automotive, Building automation, Heating technology, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Refrigeration, White goods
Related links to "Contact probe with ring and glass fibre cable"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Contact probe with ring and glass fibre cable"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Anlegefühler mit Glasseide-Leitung Vorderansicht Contact probe with glass fibre cable
€ 25,30 *
Order number: 802083-1011
Add to shopping cart
Anlegefühler mit Anlegekotz und Glasseide-Leitung - Vorderansicht Contact probe with block and glass fibre cable
€ 24,80 *
Order number: 802083-2011
Add to shopping cart
Anlegefühler mit gestuftem Anlegeklotz und Glasseide-Leitung - Vorderansicht Stepped contact probe with glass fibre cable
€ 29,24 *
Order number: 802083-3011
Add to shopping cart
Anlegefühler mit gestuftem Anlegeklotz, Widerhaken und Glasseide-Leitung - Vorderansicht Angle contact probe with glass fibre cable
€ 35,03 *
Order number: 802083-4011
Add to shopping cart
Anlegefühler mit Ring mit Silikon-Leitung - Vorderansicht Contact probe with ring and silicone cable
€ 35,08 *
Order number: 802062-1011
Add to shopping cart
Anlegefühler mit Ring mit PFA-Leitung - Vorderansicht Contact probe with ring and PFA cable
€ 40,08 *
Order number: 802072-1011
Add to shopping cart
Anlegefühler mit Kabelschuh und Glasseide-Leitung - Vorderansicht Contact probe with cable lug and glass fibre cable
€ 24,16 *
Order number: 802082-2011
Add to shopping cart