Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Cross-band probe with Screw-in thread

€ 129,10 *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to NL, BE, AT (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
PVC / PVC: -30 °C bis +105 °C
FEP / Silikon: -50 °C bis +180 °C
FEP / FEP: -50 °C bis +205 °C

keine Auswahl
(E8020) PVC/PVC (2 x 0,22 mm²)
(E8220) FEP/SIL (2 x 0,22 mm²)
(E8120) FEP/FEP (2 x 0,22 mm²)
F - Length connection cable
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector

Bitte beachten Sie den spezifizierten Temperaturbereich des Stecker / der Aderendenhülsen
isolierte Aderendhülsen: bis 80 °C
Mini-TE-Stecker: bis 220 °C
TE-Stecker: bis 220 °C

(G01) Insulated end ferrules
(G12) Mini-TC connector K gn
(G32) TC connector K gn
H - Bend protection

Der Knickschutz schützt die Anschlussleitung des Fühlers am Übergang zur Fühlerhülse vor mechanischen Belastungen (wie sie z.B. bei kleinen Biegeradien auftreten).

(H0) Without (Standard)
(H1) Metal bend protection
2.How many probes do you need?
Price calculation
Basic price
€ 129,10
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Quantity:  
Configuration is incomplete - please check it!
  • 802911-1211
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
All our cross band probes are ideal for contact temperature measurement on surfaces. Their type...more
Product information "Cross-band probe with Screw-in thread"

All our cross band probes are ideal for contact temperature measurement on surfaces. Their type is developed for the fastest surface temperature measurements and ensures the shortest response times due to the filigree head design. This type is designed to allow you to quickly and easily integrate the probe permanently into your process via the M12 screw-in thread. Alternatively, you can order this probe with anti-kink spring.

Here you can find our downloads for the Cross-band probe with Screw-in thread

pdf-download Data sheet Cross-band probe with Screw-in thread
pdf-download Instruction manual Cross-band probe with Screw-in thread
pdf-download Operating instruction Cross-band probe with Screw-in thread
pdf-download Declaration of Conformity Cross-band probe with Screw-in thread
 

Surface thermocouple - General Information

Measuring range -40 °C to +180 °C permanent, short-term up to 400 °C - The measuring range depends on the cable.
Perm. °C range cable see cable
Accuracy -40 °C to +333 °C: ±2,5 °C according to DIN IEC 60584 Class 2
Response time t63: < 0,8 s t99: < 3 s
Pull-out force ≥ 30 N
                                       

Surface thermocouple - Supply and output

Measuring element Thermocouple Type K
Measuring point Measuring point not isolated
Measurement signal Thermovoltage
 

Surface thermocouple - Ambient conditions

Protection class none (open measuring head)
Humidity and moisture condensation resistance according to application-specific qualification
 

Surface thermocouple - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Surface thermocouple - Technical Drawing

E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Surface thermocouple - Probe head

Contact geometry Cross band (fitting)
Material NiCr-Ni
Length (mm) 38
Perm. °C range + 180 °C
Diameter (mm) 12
Thread probe head M 12 x 1
 

Surface thermocouple - Thermocouple cable

Type Color Material (Outside / Inside) Perm. range °C Ø Outside (mm) Cross section (mm²) Color strand Ω / m
Thermocouple cable Type K1} PVC / PVC -30 to +105 3,8 ± 0,2 0,22  gn, wt 4,502}
Thermocouple cable Type K1} FEP / Silicone -50 to +180 3,6 ± 0,2 0,22  gn, wt 4,502}
Thermocouple compensating cable Type K1} FEP / FEP -50 to +205 4,0 ± 0,2 0,22  gn, wt 4,502}
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | 1}Color according to IEC 584 | 2}per thermocouple | Cable available as accessory
 

Surface thermocouple - Connector

Insulated end ferrules (50 mm)
Mini-TC connector Type K gn
TC connector Type K gn
 

Surface thermocouple - Bend protection

Version Without (Standard), Metal bend protection
Length (mm) 50
Material Stainless steel spring 1.4310 | SUS 302
 

Surface thermocouple - Delivery

Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Cable
 

Surface thermocouple - Important assembly advices

Our cross band probes measure the surface temperature. At the measuring point, the surface should be clean, flat and free of residues. If necessary, you can use thermal paste for better thermal coupling. Our probes are best suited for measurement on flat surfaces (1). For uneven or round surfaces, please make sure that the contact area is sufficiently large (2). If the measuring surface is too small (3), measurement errors may occur.

The filigree cross tapes are sensitive to mechanical damage. Therefore, please do not press the measuring tapes in with your fingers or with a pointed object. Carefully place the cross band probes on the measuring point and press them lightly.

Please lay the cable with reserve loop. In this way, you can extend the probe without disconnecting the electrical connection. If necessary, you should order the probe with bend protection to reduce the mechanical stress at the transition between cable and sleeve.

This type has a screw-in thread with a stop. This allows the probe to be fixed in such a way that the distance to the measuring point is defined and can be easily restored in the event of a change. For use at the measuring point, the probe is first fed through the thread with the cable and then fixed directly to the measuring point with the screw-in thread. Please make sure that you use the correct thread size at your connection point and that you make a secure connection.

 

Qualification measurement series to ensure the function of our temperature probes over their service life

Qualifizierungsmessreihe Robust even with temperature changes Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. Checkmark
Qualifizierungsmessreihe Resistant to heat and humidity Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified.        
Qualifizierungsmessreihe Long-term stable in any weather Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification.        
Qualifizierungsmessreihe Robust even under high vibration load Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g).        
Qualifizierungsmessreihe Reliable in practice: high pull-out force The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. Checkmark
Qualifizierungsmessreihe Efficient through short response time Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. Checkmark
Qualifizierungsmessreihe Corrosion-resistant even in salt spray Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years.        
Checkmark

Applicable for this probe type

Properties
Thermocouple: Type K Class 2
Temperature range: -40 °C to +180 °C
Material cable: FEP, PVC, Silicone
industry: Automotive, Cement and building materials industry, Glass industry, Machinery and apparatus engineering, Plastics industry, Power generation, Steel and iron industry, Waste recycling/incineration
Related links to "Cross-band probe with Screw-in thread"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Cross-band probe with Screw-in thread"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Kreuzbandfühler mit Ringmagnet Vorderansicht Cross-band probe with ring magnet
€ 139,60 *
Order number: 802912-1211
Add to shopping cart
Kreuzbandfühler mit Kontermutter Vorderansicht Cross-band probe with counter nut
€ 156,50 *
Order number: 802913-1211
Add to shopping cart
Kreuzbandfühler mit Sondenrohr Vorderansicht Cross-band probe with probe shaft
€ 142,00 *
Order number: 802910-1211
Add to shopping cart