Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Screw-in probe G1/2 " with PFA cable

€ 18,12 *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to NL, BE, AT (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
A - Measuring element

Bitte prüfen Sie, welches Messelement (Thermistortyp oder Pt) für Ihre Anwendung der Passende ist. Wichtige Informationen zum Messelement entnehmen Sie bitte den Kennlinien und Datenblättern. Diese finden Sie in der Langbeschreibung oder in unserem Download-Bereich.

keine Auswahl
(A011) Pt100 Class A
(A012) Pt100 Class B
(A013) Pt100 1/3 Class B
(A014) Pt100 1/10 Class B
(A022) Pt500 Class B
(A031) Pt1000 Class A
(A032) Pt1000 Class B
(A210) Ni1000
B - Connection Type

Bei Zwei-Leiter-Schaltungen addiert sich der Eigenwiderstand der Anschlussleitung zum Widerstandswert des Messwiderstands (Thermistor oder Pt) und verfälscht somit das Messergebnis. Ist der Widerstandswert des Messwiderstands groß gegenüber dem Eigenwiderstand der Anschlussleitung, so kann dieser Eigenwiderstand vernachlässigt werden. Bei Messwiderständen mit geringerem Widerstandswert (z.B. PT100), kann der Leitungseigenwiderstand die Messgenauigkeit jedoch signifikant verringern. Aus diesem Grund empfehlen wir die Zwei-Leiter-Technik in Verbindung mit kleinohmigen Messwiderständen nur dann, wenn Sie vergleichsweise kurze Anschlussleitungen, also kleinohmige Anschlussleitungen, verwenden können.

Für Applikationen, die eine sehr genaue Temperaturmessung erfordern, empfehlen wir Ihnen eine Drei- oder sogar Vier-Leiterschaltung zu verwenden.

Bei der Dreileiter-Schaltung wird der Leitungswiderstand jeder der drei angeschlossenen Leitungen mit Hilfe der dritten angeschlossenen Leitung ermittelt (alle Anschlussdrähte müssen exakt gleich lang sein) und anschließend vom gemessenen Gesamtwiderstand (Messwiderstand+Leitungswiderstand) abgezogen werden, so dass effektiv nur der Widerstandswert des Messwiderstands für die Temperaturbestimmung verwendet wird. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

Die sicherste und genaueste Messung erreichen Sie mit Hilfe einer Vierleiter-Schaltung. Hier wird auf jeder Seite des Messwiderstands eine zusätzliche Leitung angeschlossen. Zwei Leitungen dienen der Spannungsversorgung, die zwei anderen werden verwendet, um den Leitungswiderstand (ggf. auch asymmetrisch, also auch bei unterschiedlich langen Anschlussdrähtchen) zu ermitteln und vom Messwiderstandswert abzuziehen. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

(B2) 2-Wire
(B3) 3-Wire
(B4) 4-Wire
C - Mounting length

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

(C0050) 50 mm
(C0100) 100 mm
(C0150) 150 mm
(C0200) 200 mm
(C0250) 250 mm
(C0300) 300 mm
(C0400) 400 mm
(C0500) 500 mm
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
PFA: -50 °C bis +260 °C

(E5500) PFA/PFA (2 x 0,22 mm²)
(E5501) PFA/PFA (3 x 0,22 mm²)
(E5503) PFA/PFA (4 x 0,22 mm²)
F - Length connection cable

Bei sehr langen Anschlussleitungen beachten Sie bitte den Einfluss des Eigenwiderstandswerts der Leitung auf die Messgenauigkeit. Für Fühler mit Pt-oder Ni-Messelementen empfehlen wir in diesem Fall den Einsatz einer Drei- oder Vierleiterschaltung.

(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector
(G01) Insulated end ferrules
(G01) Insulated end ferrules
(G01) Insulated end ferrules
H - Bend protection

Der Knickschutz schützt die Anschlussleitung des Fühlers am Übergang zur Fühlerhülse vor mechanischen Belastungen (wie sie z.B. bei kleinen Biegeradien auftreten).

(H0) Without (Standard)
(H1) Metal bend protection
Image Changer
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Sie haben die gewünschte Kalibrierung nicht gefunden? Schreiben Sie uns gerne an webshop@testo-sensor.de. 

Sie haben weitere Fragen oder möchten herausfinden, welche Kalibrierung die richtige für Ihren Temperaturfühler ist - dafür haben wir alle Informationen auf dieser Seite für Sie zusammengefasst. Temperaturfühler kalibrieren

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration
1-Point measurement (0 °C)
1-Point measurement (60 °C)
2-Point measurement (0 °C, 60 °C)
3-Point measurement (-18 °C, 0 °C, 60 °C)
DAkkS-Calibration
3-Point measurement (-20 °C, 0 °C, 60 °C)
3.How many probes do you need?
Price calculation
Basic price
€ 18,12
A - Measuring element:  
B - Connection Type:  
C - Mounting length:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Calibration:  
ISO-Calibration:  
DAkkS-Calibration:  
Quantity:  
Configuration is incomplete - please check it!
  • 803170-1011
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Screw-in probes measure the temperature in pipelines or vessels. PFA cables can be used up to...more
Product information "Screw-in probe G1/2 " with PFA cable"

Screw-in probes measure the temperature in pipelines or vessels. PFA cables can be used up to +260 °C. They are robust, acid-resistant, flexible and a good alternative to silicone cables.

Here you can find our downloads for the Screw-in probe G1/2 " with PFA cable

pdf-download Data sheet Screw-in probe G1/2 " with PFA cable
pdf-download Instruction manual Screw-in probe G1/2 " with PFA cable
pdf-download Operating instruction Screw-in probe G1/2 " with PFA cable
pdf-download Declaration of Conformity Screw-in probe G1/2 " with PFA cable
 

Screw-in probe - General Information

Measuring range -50 °C to +260 °C depending on sensor Type and connection cable
Perm. °C range cable -50 °C to +260 °C
Accuracy depending on sensor Type
Response time t50: 9 s | t63: 13 s | t90: 30 s *
Pull-out force ≥ 30 N
* Medium1: Air (25 °C) | Medium2: Water (60°C) | Flow velocity: 0.2 m/s | Measuring element: Pt100 | More information about response time measurement here
                                       

Screw-in probe - Supply and output

Max. measurement current max. 1 mA
Supply voltage approx. 5 V depending on measurement current
Measurement signal passive (resistance value)
 

Screw-in probe - Ambient conditions

Protection class IP54 according DIN 60529 (depending on cable)
Humidity and moisture condensation resistance according to application-specific qualification
 

Screw-in probe - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Screw-in probe - Technical Drawing

A - Measuring element
B - Connection Type
C - Mounting length
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Screw-in probe - Measuring element

Measuring element Perm. range °C Accuracy / Tolerance resistance
Pt100 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt100 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Pt100 -50 °C to +200 °C 1/3 Class B dT = ±(1/3 · (0,30 °C + 0,005|t|))1}
Pt100 ±0 °C to +100 °C 1/10 Class B dT = ±(1/10 · (0,30 °C + 0,005|t|))1}
Pt500 -70 °C to +500 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Ni1000 -60 °C to +150 °C -60 °C to 0 °C: dT = ±(0,4 °C + 0,028 · T) | 0 °C to +150 °C: dT = ±(0,4 °C + 0,007 · T)
1} according to IEC 751 / EN 60751 | The measuring range depends on the measuring element and the connecting cable.
 

Screw-in probe - Possible connections

Measuring element 2W 3W 4W
NI Checkmark Checkmark Checkmark
Pt Checkmark Checkmark Checkmark
 

Screw-in probe - Screw-in thread

Thread
Material thread Stainless steel 1.4301 | SUS 304
Length (mm) 14
Thread G1/2 "
Wrench size 24
Protection sleeve
Material Stainless steel 1.4571 | 316TI
Diameter (mm)1} 6
Mounting length (mm)2} 50, 100, 150, 200, 250, 300, 400, 500
1} Tolerance ± 0,1 mm | 2} Tolerance ± 1%
 

Screw-in probe - Material connection cable

Color: white, Perm. range °C: -50 to +260
Material (Outside / Inside) Ø Outside (mm) Cross section (mm²)2} Color strand Ω / m1}
PFA / PFA 2,4 ± 0,2 2 x 0,22 rd, wt 0,09
PFA / PFA 2,4 ± 0,2 3 x 0,22 rd, wt, rd 0,09
PFA / PFA 2,7 ± 0,2 4 x 0,22 rd, wt, rd, wt 0,09
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | Cable available as accessory | 1} per single strand | 2} Tolerance ± 0,03 mm²
 

Screw-in probe - Connector

Insulated end ferrules (50 mm)
 

Screw-in probe - Bend protection

Version Without (Standard), Metal bend protection
Length (mm) 50
Material Stainless steel spring 1.4310 | SUS 302
 

Screw-in probe - Delivery

Assembly instructions via process connection
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Immersion sleeve, Heat-conducting paste
 

Screw-in probe - Important assembly advices

Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve or, when using an immersion sleeve, the Ø of the immersion sleeve. When installing in pipelines whose Ø does not have a sufficiently deep installation depth, you should install the probe either at an angle or in a pipe elbow. Make sure that you have sufficient space so that the probe can be removed again. 1) Installation with sufficient installation depth 2) Installation at an angle with small pipe Ø 3) Not like this: Minimum installation depth not reached

Installation by using an immersion sleeve (4): Please ensure that the Ø and length of the immersion sleeve are selected to suit the installation situation so that the minimum immersion depth can be achieved. Please also pay attention to the correct process connection. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal paste can improve the response times.

Please lay the cable in such a way that no water can penetrate the probe and with reserve loop (4). This allows you to extend the probe without disconnecting the electrical connection.

Properties
Measuring element: Ni1000, Pt100 1/3 Class B, Pt100 1/10 Class B, Pt100 Class A, Pt100 Class B, Pt500 Class B, Pt1000 Class A, Pt1000 Class B
Temperature range: -50 °C to +260 °C
Connection type: 2-Wire, 3-Wire, 4-Wire
Material cable: PFA
Process connection: G1/2 "
industry: Air conditioning and ventilation technology, Automotive, Building automation, Food industry, Heating technology, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Power generation, Refrigeration, White goods
Related links to "Screw-in probe G1/2 " with PFA cable"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Screw-in probe G1/2 " with PFA cable"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Einschraubfühler G1/2 " mit PVC-Leitung Vorderansicht Screw-in probe G1/2 " with PVC cable
€ 13,57 *
Order number: 803150-1011
Add to shopping cart
Einschraubfühler G1/2 " mit Glasseide-Leitung Vorderansicht Screw-in probe G1/2 " with glass fibre cable
€ 18,82 *
Order number: 803180-1011
Add to shopping cart
Einschraubfühler G1/2 " mit Silikon-Leitung Vorderansicht Screw-in probe G1/2 " with silicone cable
€ 14,62 *
Order number: 803160-1011
Add to shopping cart
Thermoelement Typ J G1/2 " mit PFA-Leitung Vorderansicht Thermocouple type J G1/2 " with PFA cable
€ 21,87 *
Order number: 803170-1111
Add to shopping cart
Thermoelement Typ K G1/2 " mit PFA-Leitung Vorderansicht Thermocouple type K G1/2 " with PFA cable
€ 21,87 *
Order number: 803170-1211
Add to shopping cart
Einschraubfühler G1/4 " mit PFA-Leitung Vorderansicht Screw-in probe G1/4 " with PFA cable
€ 17,52 *
Order number: 803170-4011
Add to shopping cart
Einschraubfühler G3/8 " mit PFA-Leitung Vorderansicht Screw-in probe G3/8 " with PFA cable
€ 17,61 *
Order number: 803170-3011
Add to shopping cart