Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Cable probe with PVC cable

6,72 € *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
A - Measuring element

Bitte prüfen Sie, welches Messelement (Thermistortyp oder Pt) für Ihre Anwendung der Passende ist. Wichtige Informationen zum Messelement entnehmen Sie bitte den Kennlinien und Datenblättern. Diese finden Sie in der Langbeschreibung oder in unserem Download-Bereich.

keine Auswahl
(A011) Pt100 Class A
(A012) Pt100 Class B
(A013) Pt100 1/3 Class B
(A014) Pt100 1/10 Class B
(A022) Pt500 Class B
(A031) Pt1000 Class A
(A032) Pt1000 Class B
(A105) NTC 5 kOhm
(A110) NTC 10 kOhm
(A120) NTC 20 kOhm
(A210) Ni1000
(A421) KTY 81-210
(A411) KTY 81-110
(A323) LM235Z
B - Connection Type

Bei Zwei-Leiter-Schaltungen addiert sich der Eigenwiderstand der Anschlussleitung zum Widerstandswert des Messwiderstands (Thermistor oder Pt) und verfälscht somit das Messergebnis. Ist der Widerstandswert des Messwiderstands groß gegenüber dem Eigenwiderstand der Anschlussleitung, so kann dieser Eigenwiderstand vernachlässigt werden. Bei Messwiderständen mit geringerem Widerstandswert (z.B. PT100), kann der Leitungseigenwiderstand die Messgenauigkeit jedoch signifikant verringern. Aus diesem Grund empfehlen wir die Zwei-Leiter-Technik in Verbindung mit kleinohmigen Messwiderständen nur dann, wenn Sie vergleichsweise kurze Anschlussleitungen, also kleinohmige Anschlussleitungen, verwenden können.

Für Applikationen, die eine sehr genaue Temperaturmessung erfordern, empfehlen wir Ihnen eine Drei- oder sogar Vier-Leiterschaltung zu verwenden.

Bei der Dreileiter-Schaltung wird der Leitungswiderstand jeder der drei angeschlossenen Leitungen mit Hilfe der dritten angeschlossenen Leitung ermittelt (alle Anschlussdrähte müssen exakt gleich lang sein) und anschließend vom gemessenen Gesamtwiderstand (Messwiderstand+Leitungswiderstand) abgezogen werden, so dass effektiv nur der Widerstandswert des Messwiderstands für die Temperaturbestimmung verwendet wird. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

Die sicherste und genaueste Messung erreichen Sie mit Hilfe einer Vierleiter-Schaltung. Hier wird auf jeder Seite des Messwiderstands eine zusätzliche Leitung angeschlossen. Zwei Leitungen dienen der Spannungsversorgung, die zwei anderen werden verwendet, um den Leitungswiderstand (ggf. auch asymmetrisch, also auch bei unterschiedlich langen Anschlussdrähtchen) zu ermitteln und vom Messwiderstandswert abzuziehen. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

(B2) 2-Wire
(B3) 3-Wire
(B4) 4-Wire
C - Length protection sleeve

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

(C0030) 30 mm
(C0040) 40 mm
(C0050) 50 mm
(C0060) 60 mm
(C0100) 100 mm
(C0200) 200 mm
D - Diameter protection sleeve

Bei Temperaturmessungen in Festkörpern oder wenn der Fühler in einer Tauchhülse montiert ist, verlangsamt die den Fühler umgebende Luft die Wärmeleitung vom Medium zum Fühler. Dadurch wird auch die Temperaturmessung verlangsamt und führt im Extremfall zu falschen Temperaturmesswerten. Achten Sie bitte deshalb darauf, dass der Temperaturfühler wärmetechnisch bestmöglich an Ihr Messmedium angekoppelt ist, d.h. wählen Sie den Hülsendurchmesser so aus, dass der Luftspalt so klein wie möglich wird.

(D040) Ø 4,0 mm
(D050) Ø 5,0 mm
(D060) Ø 6,0 mm
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
PVC -30 °C bis +105 °C

(E0000) PVC/PVC (2 x 0,22 mm²)
(E0001) PVC/PVC (3 x 0,22 mm²)
(E0002) PVC/PVC (4 x 0,22 mm²)
(E0006) PVC/PVC (2 x 0,22 mm²)
(E0007) PVC/PVC (3 x 0,14 mm²)
(E0008) PVC/PVC (4 x 0,14 mm²)
(E0009) PVC/PVC (2 x 0,14 mm²)
F - Length connection cable

Bei sehr langen Anschlussleitungen beachten Sie bitte den Einfluss des Eigenwiderstandswerts der Leitung auf die Messgenauigkeit. Für Fühler mit Pt-oder Ni-Messelementen empfehlen wir in diesem Fall den Einsatz einer Drei- oder Vierleiterschaltung.

(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector
(G01) Insulated end ferrules
(G01) Insulated end ferrules
(G01) Insulated end ferrules
H - Bend protection
(H0) Without (Standard)
Image Changer
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Sie haben die gewünschte Kalibrierung nicht gefunden? Schreiben Sie uns gerne an webshop@testo-sensor.de. 

Sie haben weitere Fragen oder möchten herausfinden, welche Kalibrierung die richtige für Ihren Temperaturfühler ist - dafür haben wir alle Informationen auf dieser Seite für Sie zusammengefasst. Temperaturfühler kalibrieren

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

1-Point measurement (0 °C)
1-Point measurement (60 °C)
2-Point measurement (0 °C, 60 °C)
3-Point measurement (-18 °C, 0 °C, 60 °C)
DAkkS-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

3-Point measurement (-20 °C, 0 °C, 60 °C)
3.How many probes do you need?
Price calculation
Basic price
6,72 €
A - Measuring element:  
B - Connection Type:  
C - Length protection sleeve:  
D - Diameter protection sleeve:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Calibration:  
ISO-Calibration:  
DAkkS-Calibration:  
Quantity:  
Configuration is incomplete - please check it!
  • 803550-1011
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Cable probes with PVC cable are the most cost-efficient solution for many applications up to...more
Product information "Cable probe with PVC cable"

Cable probes with PVC cable are the most cost-efficient solution for many applications up to +105 °C. If other temperatures or higher flexibility are required, cables made of silicone, glass fibre cable or PFA are used.

Here you can find our downloads for the Cable probe with PVC cable

pdf-download Data sheet Cable probe with PVC cable
pdf-download Instruction manual Cable probe with PVC cable
pdf-download Operating instruction Cable probe with PVC cable
pdf-download Declaration of Conformity Cable probe with PVC cable
step-download Step files Cable probe with PVC cable
 

Cable probe - General Information

Measuring range -30 °C to +105 °C depending on sensor Type and connection cable
Perm. °C range cable -30 °C to +105 °C
Accuracy depending on sensor Type
Response time t50: 5 s | t63: 7 s | t90: 13 s *
Pull-out force ≥ 30 N

* Medium1: Air (25 °C) | Medium2: Water (60°C) | Flow velocity: 0.2 m/s | Measuring element: Pt100 | More information about response time measurement here

                                       

Cable probe - Supply and output

Max. measurement current max. 1 mA
Supply voltage approx. 5 V depending on measurement current
Measurement signal passive (resistance value)
 

Cable probe - Ambient conditions

Protection class IP65 according DIN 60529 (depending on cable)
Humidity and moisture condensation resistance according to application-specific qualification
 

Cable probe - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
 

Cable probe - Technical Drawing

A - Measuring element
B - Connection Type
C - Length protection sleeve
D - Diameter protection sleeve
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Cable probe - Measuring element

Measuring element Perm. range °C Accuracy / Tolerance resistance
Pt100 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt100 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Pt100 -50 °C to +200 °C 1/3 Class B dT = ±(1/3 · (0,30 °C + 0,005|t|))1}
Pt100 ±0 °C to +100 °C 1/10 Class B dT = ±(1/10 · (0,30 °C + 0,005|t|))1}
Pt500 -70 °C to +500 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
NTC 5 kOhm -40 °C to +125 °C R25 = 5 KOhm ±1 %
NTC 10 kOhm -40 °C to +125 °C R25 = 10 KOhm ±1 %
NTC 20 kOhm -40 °C to +125 °C R25 = 20 KOhm ±1 %
KTY 81-210 -50 °C to +150 °C R25 = 2 KOhm ±1 %
KTY 81-110 -50 °C to +150 °C R25 = 1 KOhm ±1 %
LM235Z -40 °C to +125 °C typical ±1 °C
Ni1000 -60 °C to +150 °C -60 °C to 0 °C: dT = ±(0,4 °C + 0,028 · T) | 0 °C to +150 °C: dT = ±(0,4 °C + 0,007 · T)
1} according to IEC 751 / EN 60751 | Please note that the measuring range depends on the measuring element and the connection cable.
 

Cable probe - Possible connections

Measuring element 2W 3W 4W
NTC Checkmark    
KTY Checkmark    
LM235Z Checkmark    
NI Checkmark Checkmark Checkmark
Pt Checkmark Checkmark Checkmark
 

Cable probe - Protection sleeve

Diameter (mm)1} 4, 5, 6
Length (mm)2} 30, 40, 50, 60, 100, 200
1} Tolerance ± 0,1 mm | 2} Tolerance length ≤ 100: ± 1 mm / length > 100: ± 1 %
 

Cable probe - Material and possible configuration

Length / Ø (mm) 3 4 5 6
30 not available Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
40 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
50 not available Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L Stainless steel 1.4404 | 316L
60 not available not available not available Stainless steel 1.4571 | 316TI
100 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI
200 not available Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI Stainless steel 1.4571 | 316TI
other protective sleeve lengths and Ø available on request
 

Cable probe - Material connection cable

Color: black, Perm. range °C: -30 to +105
Perm. Ø mm Material (Outside / Inside) Ø Outside (mm) Cross section (mm²)2} Color strand Ω / m1}
6 PVC / PVC 4,8 ± 0,2 2 x 0,22 rd, wt 0,07
6 PVC / PVC 4,8 ± 0,2 3 x 0,22 rd, wt, rd 0,07
6 PVC / PVC 4,8 ± 0,2 4 x 0,22 rd, wt, rd, wt 0,07
5 PVC / PVC 4,0 ± 0,2 2 x 0,22 rd, wt 0,07
5 PVC / PVC 3,8 ± 0,2 3 x 0,14 rd, wt, rd 0,13
5 PVC / PVC 3,8 ± 0,2 4 x 0,14 rd, wt, rd, wt 0,13
4 PVC / PVC 3,2 ± 0,2 2 x 0,14 rd, wt 0,13
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | Cable available as accessory | 1} per single strand | 2} Tolerance ± 0,03 mm²
 

Cable probe - Connector

Insulated end ferrules (50 mm)
 

Cable probe - Delivery

Assembly instructions by using compression fitting or immersion sleeve
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Immersion sleeve, Heat-conducting paste, Compression fitting, Quick-release strap
 

Cable probe - Important assembly advices

Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible in the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve or, when using an immersion sleeve, the Ø of the immersion sleeve. When installing in pipelines whose Ø does not have a sufficiently deep installation depth, you should install the probe either at an angle or in a pipe elbow. Make sure that there is sufficient space for the probe to be removed. 1) Installation with sufficient installation depth 2) Installation at an angle with small pipe Ø 3) Not like this: Minimum installation depth not reached

Installation by means of compression fitting: Please tighten the union nut of the compression fitting by hand as far as it will go (clearly noticeable). For compression fittings with PTFE pressure ring, please make a 1/4 turn with a wrench suitable for the width across flats. These compression fittings can be used several times in this way. In the case of compression fittings with stainless steel cutting ring, the compression fitting connects to the protection tube. This connection is pressure resistant up to 40 bar. However, the compression fitting can only be used once. It must also be tightened more firmly. Please tighten it with 1 3/4 turns.

Mounting by using an immersion sleeve (4): Please note that the Ø and the length of the immersion sleeve must be selected to suit the installation situation so that the minimum immersion depth can be achieved. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal paste can improve the response times.

Please lay the cable with reserve loop (4) and in such a way that no water can penetrate the sensor head. This allows you to extend the probe without disconnecting the electrical connection.

Properties
Kalibrierung: DAkkS-Kalibrierung, ISO-Kalibrierung
Measuring element: KTY 81-110, KTY 81-210, LM235Z, Ni1000, NTC 5 kOhm, NTC 10 kOhm, NTC 20 kOhm, Pt100 1/3 Class B, Pt100 1/10 Class B, Pt100 Class A, Pt100 Class B, Pt500 Class B, Pt1000 Class A, Pt1000 Class B
Temperature range: -30 °C to +105 °C
Connection type: 2-Wire, 3-Wire, 4-Wire
Material cable: PVC
industry: Air conditioning and ventilation technology, Automotive, Building automation, Food industry, Heating technology, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Refrigeration, White goods
Related links to "Cable probe with PVC cable"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Cable probe with PVC cable"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Kabelfühler verjüngt mit PVC-Leitung - Vorderansicht Cable probe tapered with PVC cable
25,85 € *
Order number: 803551-1011
Add to shopping cart
Kabelfühler abgesetzt mit PVC-Leitung - Vorderansicht Cable probe stepped with PVC cable
28,63 € *
Order number: 803552-1011
Add to shopping cart
Kabel-Thermoelement Typ J mit PVC-Leitung Vorderansicht Cable thermocouple type J with PVC cable
7,88 € *
Order number: 803550-1111
Add to shopping cart
Kabel-Thermoelement Typ K mit PVC-Leitung Vorderansicht Cable thermocouple type K with PVC cable
7,88 € *
Order number: 803550-1211
Add to shopping cart
Hutschienen-Transmitter + Kabelfühler PVC-Leitung - Vorderansicht Hat rail transmitter + cable probe PVC cable
65,62 € *
Order number: 803550-1091
Add to shopping cart
Kabelfühler mit Silikon-Leitung Vorderansicht Cable probe with silicone cable
7,77 € *
Order number: 803560-1011
Add to shopping cart
Kabelfühler mit Glasseide-Leitung Vorderansicht Cable probe with glass fibre cable
11,97 € *
Order number: 803580-1011
Add to shopping cart
Kabelfühler mit PFA-Leitung Vorderansicht Cable probe with PFA cable
11,27 € *
Order number: 803570-1011
Add to shopping cart