Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
9,48 € *
Prices plus VAT plus shipping costs of 4,95 to GER (incl. VAT)
Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)
Repeated order: check settings carefully and change if necessary.
1.Configure and order now
E - Material connection cable

F - Length cable








G - Connector


2.How many probes do you need?
Price calculation
Basic price
9,48 €
E - Material connection cable: | ||
F - Length cable: | ||
G - Connector: | ||
Quantity: |
Your Price:
9,48 € * [ 9,48 € GROSS ]
[ GROSS ]
rounded up to minimum price
Prices plus VAT plus shipping costs of 4,95 to GER (incl. VAT)
- Order number: 803910-1211
Our Payments
Advantages
- We are ready to deliver: All information here
- Advice directly from experts
- Quality directly from the manufacturer
- Long-term stable temperature probes over years
- B2B customers welcome: All information here

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Thermocouples have a simple structure. The two thermocouple wires are welded at the tip and...more
Product information "Thermocouple type K"
Thermocouples have a simple structure. The two thermocouple wires are welded at the tip and remain without a protection sleeve. Therefore, thermocouples are characterized by particularly fast response times and a wide range of applications. The thermocouples can be used in a temperature range from -40 °C to +350 °C.
Here you can find our downloads for the Thermocouple type K
![]() | Data sheet Thermocouple type K |
![]() | Instruction manual Thermocouple type K |
![]() | Operating instruction Thermocouple Type K |
![]() | Declaration of Conformity Thermocouple type K |
Thermocouple - General Information | |||||||||||||||||||
Measuring range | -40 °C to +350 °C | ||||||||||||||||||
Perm. °C range cable | -50 °C to +350 °C | ||||||||||||||||||
Accuracy | -40 °C to +375 °C: ±1,5 °C according to DIN IEC 60584 Class 1 | ||||||||||||||||||
Response time | t63 / t99: information is available on request | ||||||||||||||||||
Pull-out force | ≥ 30 N | ||||||||||||||||||
Thermocouple - Supply and output | |||||||||||||||||||
Measuring element | Thermocouple Type K | ||||||||||||||||||
Measuring point | Welding point not insulated | ||||||||||||||||||
Measurement signal | Thermovoltage | ||||||||||||||||||
Thermocouple - Ambient conditions | |||||||||||||||||||
Protection class | IP20 according DIN 60529 | ||||||||||||||||||
Humidity and moisture condensation resistance | according to application-specific qualification | ||||||||||||||||||
Thermocouple - Certificates and Standards | |||||||||||||||||||
Standards | DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05 | ||||||||||||||||||
Directive | RoHS 2011/65/EU | 2014/30/EU | ||||||||||||||||||
Certificates | Certificate of suitability (on request) | ||||||||||||||||||
Thermocouple - Technical Drawing | |||||||||||||||||||
![]() | |||||||||||||||||||
E - Material connection cable | |||||||||||||||||||
F - Length connection cable | |||||||||||||||||||
![]() | |||||||||||||||||||
G - Connector | |||||||||||||||||||
All dimensions in mm | |||||||||||||||||||
Thermocouple - Thermocouple cable | |||||||||||||||||||
![]() | Type | Color | Material (Outside / Inside) | Perm. range °C | Sheath (mm)2} | Cross section (mm²) | Color Leads | Ω / m | |||||||||||
Thermocouple cable | Type K1} | Glass fibre / Glass fibre | -50 to +350 | 2,0 x 1,2 | 0,2 | gn, wt | 2,002} | ||||||||||||
Length (m) | 1, 2, 3, 4, 5, 10, 15, 20 | ||||||||||||||||||
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | 1}Color according to IEC 584 | 2}per thermocouple | Cable available as accessory | |||||||||||||||||||
Thermocouple - Connector | |||||||||||||||||||
![]() | Mini-TC connector Type K gn | ||||||||||||||||||
![]() | Mini-TC connector Type K ye | ||||||||||||||||||
Thermocouple - Delivery | |||||||||||||||||||
Delivery and Packaging | Probe, seperatly packaged in PE bag | ||||||||||||||||||
Matching accessories | Connectors, couplings | ||||||||||||||||||
Qualification measurement series to ensure the function of our temperature probes over their service life | |||||||||||||||||||
![]() | Robust even with temperature changes | Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. | ![]() | ||||||||||||||||
![]() | Resistant to heat and humidity | Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified. | |||||||||||||||||
![]() | Long-term stable in any weather | Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification. | |||||||||||||||||
![]() | Robust even under high vibration load | Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g). | ![]() | ||||||||||||||||
![]() | Reliable in practice: high pull-out force | The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. | ![]() | ||||||||||||||||
![]() | Efficient through short response time | Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. | ![]() | ||||||||||||||||
![]() | Corrosion-resistant even in salt spray | Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years. | |||||||||||||||||
![]() Applicable for this probe type |
Properties
industry: | Automotive, Building automation, Glass industry, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Power generation, Steel and iron industry |
Material cable: | Glass fibre |
Thermocouple: | Type K Class 1 |
Temperature range: | -40 °C to +350 °C |
Related links to "Thermocouple type K"
Available downloads:
- Download Datenblatt Thermopaar Typ K
- Download Bedienungsansleitung Thermopaar Typ K
- Download Konformitätserklärung Thermopaar Typ K
- Download Kennlinie Thermoelement Typ K
- Download Characteristic thermocouple type K
- Download Betriebsanleitung Thermoelemente
- Download Operating instructions Thermocouple
Read, write and discuss reviews...more
Customer evaluation for "Thermocouple type K"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
16,69 € *
Order number: 802311-1211
Add to shopping cart