Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Thermocouple type J

9,48 € *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
E - Material connection cable
(E8311) GLS/GLS (2 x 0,2 mm²)
F - Length cable
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector
(G11) Mini-TC connector J bk
2.How many probes do you need?
Price calculation
Basic price
9,48 €
E - Material connection cable:  
F - Length cable:  
G - Connector:  
Quantity:  
Configuration is incomplete - please check it!
  • 803910-1111
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Thermocouples have a simple structure. The two thermocouple wires are welded at the tip and...more
Product information "Thermocouple type J"

Thermocouples have a simple structure. The two thermocouple wires are welded at the tip and remain without a protection sleeve. Therefore, thermocouples are characterized by particularly fast response times and a wide range of applications. The thermocouples can be used in a temperature range from -40 °C to +350 °C.

Here you can find our downloads for the Thermocouple type J

pdf-download Data sheet Thermocouple type J
pdf-download Instruction manual Thermocouple type J
pdf-download Operating instruction Thermocouple Type J
pdf-download Declaration of Conformity Thermocouple type J
 

Thermocouple - General Information

Measuring range -40 °C to +350 °C
Perm. °C range cable -50 °C to +350 °C
Accuracy -40 °C to +375 °C: ±1,5 °C according to DIN IEC 60584 Class 1
Response time t63 / t99: information is available on request
Pull-out force ≥ 30 N
                                       

Thermocouple - Supply and output

Measuring element Thermocouple Type J
Measuring point Welding point not insulated
Measurement signal Thermovoltage
 

Thermocouple - Ambient conditions

Protection class IP20 according DIN 60529 
Humidity and moisture condensation resistance according to application-specific qualification
 

Thermocouple - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Thermocouple - Technical Drawing

E - Material connection cable
F - Length connection cable
G - Connector
All dimensions in mm
 

Thermocouple - Thermocouple cable

Type Color Material (Outside / Inside) Perm. range °C Sheath (mm)2} Cross section (mm²) Color Leads Ω / m
Thermocouple cable Type J1} Glass fibre / Glass fibre -50 to +350 2,2 x 1,2 0,2  bk, wt 1,252}
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | 1}Color according to IEC 584 | 2}per thermocouple | Cable available as accessory
 

Thermocouple - Connector

Mini-TC connector Type J bk
 

Thermocouple - Delivery

Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Connectors, couplings
 

Qualification measurement series to ensure the function of our temperature probes over their service life

Qualifizierungsmessreihe Robust even with temperature changes Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. Checkmark
Qualifizierungsmessreihe Resistant to heat and humidity Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified.        
Qualifizierungsmessreihe Long-term stable in any weather Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification.        
Qualifizierungsmessreihe Robust even under high vibration load Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g). Checkmark
Qualifizierungsmessreihe Reliable in practice: high pull-out force The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. Checkmark
Qualifizierungsmessreihe Efficient through short response time Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. Checkmark
Qualifizierungsmessreihe Corrosion-resistant even in salt spray Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years.        
Checkmark

Applicable for this probe type

Properties
Thermocouple: Type J Class 1
Temperature range: -40 °C to +350 °C
Material cable: Glass fibre
industry: Automotive, Building automation, Glass industry, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Power generation, Steel and iron industry
Related links to "Thermocouple type J"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Thermocouple type J"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Mantelthermoelement Typ J mit Leitung Vorderansicht Sheathed thermocouple type J with cable
23,80 € *
Order number: 802310-1111
Add to shopping cart
Mantelthermoelement Typ J mit TE-Stecker Vorderansicht Sheathed thermocouple type J with TC-connector
16,69 € *
Order number: 802311-1111
Add to shopping cart
Thermopaar Typ K Vorderansicht Thermocouple type K
9,48 € *
Order number: 803910-1211
Add to shopping cart