Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Air temperature probe with PVC cable

€ 24,80 *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 6 Workdays to NL, BE, AT (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configuration
A - Measuring element

Bitte prüfen Sie, welches Messelement (Thermistortyp oder Pt) für Ihre Anwendung der Passende ist. Wichtige Informationen zum Messelement entnehmen Sie bitte den Kennlinien und Datenblättern. Diese finden Sie in der Langbeschreibung oder in unserem Download-Bereich.

keine Auswahl
(A011) Pt100 Class A
(A012) Pt100 Class B
(A013) Pt100 1/3 Class B
(A014) Pt100 1/10 Class B
(A022) Pt500 Class B
(A031) Pt1000 Class A
(A032) Pt1000 Class B
(A105) NTC 5 kOhm
(A110) NTC 10 kOhm
(A120) NTC 20 kOhm
(A210) Ni1000
B - Connection Type

Bei Zwei-Leiter-Schaltungen addiert sich der Eigenwiderstand der Anschlussleitung zum Widerstandswert des Messwiderstands (Thermistor oder Pt) und verfälscht somit das Messergebnis. Ist der Widerstandswert des Messwiderstands groß gegenüber dem Eigenwiderstand der Anschlussleitung, so kann dieser Eigenwiderstand vernachlässigt werden. Bei Messwiderständen mit geringerem Widerstandswert (z.B. PT100), kann der Leitungseigenwiderstand die Messgenauigkeit jedoch signifikant verringern. Aus diesem Grund empfehlen wir die Zwei-Leiter-Technik in Verbindung mit kleinohmigen Messwiderständen nur dann, wenn Sie vergleichsweise kurze Anschlussleitungen, also kleinohmige Anschlussleitungen, verwenden können.

Für Applikationen, die eine sehr genaue Temperaturmessung erfordern, empfehlen wir Ihnen eine Drei- oder sogar Vier-Leiterschaltung zu verwenden.

Bei der Dreileiter-Schaltung wird der Leitungswiderstand jeder der drei angeschlossenen Leitungen mit Hilfe der dritten angeschlossenen Leitung ermittelt (alle Anschlussdrähte müssen exakt gleich lang sein) und anschließend vom gemessenen Gesamtwiderstand (Messwiderstand+Leitungswiderstand) abgezogen werden, so dass effektiv nur der Widerstandswert des Messwiderstands für die Temperaturbestimmung verwendet wird. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

Die sicherste und genaueste Messung erreichen Sie mit Hilfe einer Vierleiter-Schaltung. Hier wird auf jeder Seite des Messwiderstands eine zusätzliche Leitung angeschlossen. Zwei Leitungen dienen der Spannungsversorgung, die zwei anderen werden verwendet, um den Leitungswiderstand (ggf. auch asymmetrisch, also auch bei unterschiedlich langen Anschlussdrähtchen) zu ermitteln und vom Messwiderstandswert abzuziehen. Diese Subtraktion kann beispielsweise in der Messelelektronik automatisch durchgeführt werden.

(B2) 2-Wire
(B3) 3-Wire
(B4) 4-Wire
C - Length protection sleeve

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

(C0100) 100 mm
(C0200) 200 mm
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
PVC -30 °C bis +105 °C

(E0000) PVC/PVC (2 x 0,22 mm²)
(E0001) PVC/PVC (3 x 0,22 mm²)
(E0002) PVC/PVC (4 x 0,22 mm²)
F - Length connection cable

Bei sehr langen Anschlussleitungen beachten Sie bitte den Einfluss des Eigenwiderstandswerts der Leitung auf die Messgenauigkeit. Für Fühler mit Pt-oder Ni-Messelementen empfehlen wir in diesem Fall den Einsatz einer Drei- oder Vierleiterschaltung.

(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector
(G01) Insulated end ferrules
(G01) Insulated end ferrules
(G01) Insulated end ferrules
H - Bend protection

Der Knickschutz schützt die Anschlussleitung des Fühlers am Übergang zur Fühlerhülse vor mechanischen Belastungen (wie sie z.B. bei kleinen Biegeradien auftreten).

(H0) Without (Standard)
(H1) Metal bend protection
Image Changer
2.How many probes do you need?
Price calculation
Basic price
€ 24,80
A - Measuring element:  
B - Connection Type:  
C - Length protection sleeve:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Quantity:  
Configuration is incomplete - please check it!
  • 803753-1011
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Air temperature probes are used for temperature measurement in gaseous media such as air ducts....more
Product information "Air temperature probe with PVC cable"

Air temperature probes are used for temperature measurement in gaseous media such as air ducts. Our air probes with PVC cable can be used in the temperature range from -30 to +105°C. The temperature sensor sits in a perforated stainless steel sleeve that protects the sensor while providing a fast response time.

Here you can find our downloads for the Air temperature probe with PVC cable

pdf-download Data sheet Air temperature probe with PVC cable
pdf-download Instruction manual Air temperature probe with PVC cable
pdf-download Operating instruction Air temperature probe with PVC cable
pdf-download Declaration of Conformity Air temperature probe with PVC cable
 

Air probe - General Information

Measuring range -30 °C to +105 °C depending on sensor Type and connection cable
Perm. °C range cable -30 °C to +105 °C
Accuracy depending on sensor Type
Response time t63 / t99: information is available on request
Pull-out force ≥ 30 N
                                       

Air probe - Supply and output

Max. measurement current max. 1 mA
Supply voltage approx. 5 V depending on measurement current
Measurement signal passive (resistance value)
 

Air probe - Ambient conditions

Protection class none (measuring element is exposed)
Humidity and moisture condensation resistance according to application-specific qualification
 

Air probe - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Air probe - Technical Drawing

A - Measuring element
B - Connection Type
C - Length protection sleeve
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Air probe - Measuring element

Measuring element Perm. range °C Accuracy / Tolerance resistance
Pt100 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt100 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
Pt100 -50 °C to +200 °C 1/3 Class B dT = ±(1/3 · (0,30 °C + 0,005|t|))1}
Pt100 ±0 °C to +100 °C 1/10 Class B dT = ±(1/10 · (0,30 °C + 0,005|t|))1}
Pt500 -70 °C to +500 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +400 °C Class B dT = ±(0,30 °C + 0,005|t|)1}
Pt1000 -50 °C to +300 °C Class A dT = ±(0,15 °C + 0,002|t|)1}
NTC 5 kOhm -40 °C to +125 °C R25 = 5 KOhm ±1 %
NTC 10 kOhm -40 °C to +125 °C R25 = 10 KOhm ±1 %
NTC 20 kOhm -40 °C to +125 °C R25 = 20 KOhm ±1 %
Ni1000 -60 °C to +150 °C -60 °C to 0 °C: dT = ±(0,4 °C + 0,028 · T) | 0 °C to +150 °C: dT = ±(0,4 °C + 0,007 · T)
1} according to IEC 751 / EN 60751 | Please note that the measuring range depends on the measuring element and the connecting cable.
 

Air probe - Possible connections

Measuring element 2W 3W 4W
NTC Checkmark    
NI Checkmark Checkmark Checkmark
Pt Checkmark Checkmark Checkmark
 

Air probe - Protection sleeve

Material Stainless steel 1.4571 | 316TI
Diameter (mm)1} 6
Length (mm)2} 100, 200
1} Tolerance ± 0,1 mm | 2} Tolerance ± 1%
 

Air probe - Material connection cable

Color: black, Perm. range °C: -30 to +105
Material (Outside / Inside) Ø Outside (mm) Cross section (mm²)2} Color strand Ω / m1}
PVC / PVC 4,8 ± 0,2 2 x 0,22 rd, wt 0,07
PVC / PVC 4,8 ± 0,2 3 x 0,22 rd, wt, rd 0,07
PVC / PVC 4,8 ± 0,2 4 x 0,22 rd, wt, rd, wt 0,07
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | Cable available as accessory | 1} per single strand | 2} Tolerance ± 0,03 mm²
 

Air probe - Connector

Insulated end ferrules (50 mm)
 

Air probe - Bend protection

Version Without (Standard), Metal bend protection
Length (mm) 50
Material Stainless steel spring 1.4310 | SUS 302
 

Air probe - Delivery

Assembly instructions by using a compression fitting or immersion sleeve | The exposed measuring element is sensitive to mechanical damage. Therefore, please do not press in the tip of the sleeve with your fingers or with a pointed object.
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Compression fitting, Mounting flange
 

Qualification measurement series to ensure the function of our temperature probes over their service life

Qualifizierungsmessreihe Robust even with temperature changes Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. Checkmark
Qualifizierungsmessreihe Resistant to heat and humidity Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified.        
Qualifizierungsmessreihe Long-term stable in any weather Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification.        
Qualifizierungsmessreihe Robust even under high vibration load Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g).        
Qualifizierungsmessreihe Reliable in practice: high pull-out force The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. Checkmark
Qualifizierungsmessreihe Efficient through short response time Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. Checkmark
Qualifizierungsmessreihe Corrosion-resistant even in salt spray Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years.        
Checkmark

Applicable for this probe type

Properties
Measuring element: Ni1000, NTC 5 kOhm, NTC 10 kOhm, NTC 20 kOhm, Pt100 1/3 Class B, Pt100 1/10 Class B, Pt100 Class A, Pt100 Class B, Pt500 Class B, Pt1000 Class A, Pt1000 Class B
Temperature range: -30 °C to +105 °C
Connection type: 2-Wire, 3-Wire, 4-Wire
Material cable: PVC
industry: Air conditioning and ventilation technology, Building automation, Heating technology, Machinery and apparatus engineering, Refrigeration
Related links to "Air temperature probe with PVC cable"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Air temperature probe with PVC cable"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Kanalfühler mit Gehäuse und Kunststoffflansch Vorderansicht Duct probe with housing and plastic flange
€ 26,77 *
Order number: 803710-1011
Add to shopping cart
Mittelwertfühler Vorderansicht Average value probe
€ 88,23 *
Order number: 803712-1011
Add to shopping cart
Kanalfühler mit J-Kopf und Kunststoffflansch Vorderansicht Duct probe with J-Head and plastic flange
€ 38,61 *
Order number: 803711-1011
Add to shopping cart
Lufttemperaturfühler mit PVC-Leitung - Vorderansicht Air temperature probe with silicone cable
€ 26,80 *
Order number: 803763-1011
Add to shopping cart
Lufttemperaturfühler mit PFA-Leitung - Vorderansicht Air temperature probe with PFA cable
€ 31,30 *
Order number: 803773-1011
Add to shopping cart
Lufttemperaturfühler mit Glasseide-Leitung - Vorderansicht Air temperature probe with glass fibre cable
€ 32,30 *
Order number: 803783-1011
Add to shopping cart