Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Sheathed thermocouple type J with TC-connector

16,69 € *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
C - Length protection sleeve

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

keine Auswahl
(C0100) 100 mm
(C0150) 150 mm
(C0200) 200 mm
(C0250) 250 mm
(C0400) 400 mm
(C0500) 500 mm
(C1000) 1000 mm
D - Diameter protection sleeve

Bei Temperaturmessungen in Festkörpern oder wenn der Fühler in einer Tauchhülse montiert ist, verlangsamt die den Fühler umgebende Luft die Wärmeleitung vom Medium zum Fühler. Dadurch wird auch die Temperaturmessung verlangsamt und führt im Extremfall zu falschen Temperaturmesswerten. Achten Sie bitte deshalb darauf, dass der Temperaturfühler wärmetechnisch bestmöglich an Ihr Messmedium angekoppelt ist, d.h. wählen Sie den Hülsendurchmesser so aus, dass der Luftspalt so klein wie möglich wird.

(D015) Ø 1,5 mm
(D030) Ø 3,0 mm
(D060) Ø 6,0 mm
G - Connector

Bitte beachten Sie den spezifizierten Temperaturbereich des Stecker / der Aderendenhülsen
Mini-TE-Stecker: bis 220 °C
TE-Stecker: bis 220 °C

(G11) Mini-TC connector J bk
(G31) TC connector J bk
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Didn't find the calibration you were looking for? Feel free to write to us at webshop@testo-sensor.de. 

Do you have further questions or want to find out which calibration is right for your temperature sensor? We have summarized all the information on this page for you. Calibrate temperature probes

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

1-Point measurement (60 °C)
3-Point measurement (0 °C, 150 °C, 300 °C)
3-Point measurement (0 °C, 300 °C, 600 °C)
DAkkS-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

3-Point measurement (-20 °C, 0 °C, 60 °C)
3-Point measurement (0 °C, 100 °C, 200 °C)
3.How many probes do you need?
Price calculation
Basic price
16,69 €
C - Length protection sleeve:  
D - Diameter protection sleeve:  
G - Connector:  
Calibration:  
ISO-Calibration:  
DAkkS-Calibration:  
Quantity:  
Configuration is incomplete - please check it!
  • 802311-1111
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Sheathed thermocouples with connectors are mineral insulated. We manufacture them from...more
Product information "Sheathed thermocouple type J with TC-connector"

Sheathed thermocouples with connectors are mineral insulated. We manufacture them from high-quality materials in a robust type. They are flexible and can thus be used flexibly in the high temperature range from -40 °C to 750 °C.

Here you can find our downloads for the Sheathed thermocouple type J with TC-connector

pdf-download Data sheet Sheathed thermocouple type J with TC-connector
pdf-download Instruction manual Sheathed thermocouple type J with TC-connector
pdf-download Operating instruction Sheathed thermocouple Type J with TC-connector
pdf-download Declaration of Conformity Sheathed thermocouple type J with TC-connector
 

Sheathed thermocouple - General Information

Measuring range -40 °C to +750 °C
Accuracy Class 1 1}: -40 °C bis +375 °C: ±1,5 °C | 375 °C bis 750 °C: ±0,004 |t| 2}
Response time t63 / t99: information is available on request
1} according to DIN IEC 60584 2} If the thermocouple is operated outside the specified measuring range of its respective tolerance class, irreversible changes may also occur on the thermocouple, which subsequently leads to a measurement deviation (even within the specified range).
                                       

Sheathed thermocouple - Supply and output

Measuring element Thermocouple Type J
Measuring point Measuring point isolated
Measurement signal Thermovoltage
 

Sheathed thermocouple - Ambient conditions

Protection class IP68 (protective tube) according to DIN 60529 
Humidity and moisture condensation resistance according to application-specific qualification
 

Sheathed thermocouple - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
Certificates Certificate of suitability (on request)
 

Sheathed thermocouple - Technical Drawing

C - Length protection sleeve
D - Diameter protection sleeve
G - Connector
All dimensions in mm
 

Sheathed thermocouple - Protection sleeve

Material Stainless steel 1.4541 | SUS321
Diameter (mm)1} 1,5, 3, 6
Length (mm)2} 100, 150, 200, 250, 300, 400, 500, 1000, 1500
1} Tolerance ± 0,1 mm | 2} Tolerance ± 1% | Please note: Length of = C - 2 mm
 

Sheathed thermocouple - Connector

Mini-TC connector Type J bk
TC connector Type J bk
 

Sheathed thermocouple - Delivery

Assembly instructions by using an compression fitting or immersion sleeve
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Immersion sleeve, Heat-conducting paste, Compression fitting
 

Sheathed thermocouple - Important assembly advices

Measuring errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible into the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve or, when using an immersion sleeve, the Ø of the immersion sleeve. When installing in pipelines whose Ø does not have a sufficiently deep installation depth, you should install the probe either at an angle or in a pipe elbow. Make sure that there is sufficient space for the probe to be removed. 1) Installation with sufficient installation depth 2) Installation at an angle with small pipe Ø 3) Not like this: Minimum installation depth not reached

Installation by using an immersion sleeve (4): Please ensure that the Ø and length of the immersion sleeve are selected to suit the installation situation so that the minimum immersion depth can be achieved. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal paste can improve the response times.

Please pay attention to the bending radius. This should be at least 5 X D of the outer diameter of the sheathed thermocouple.

 

Qualification measurement series to ensure the function of our temperature probes over their service life

Qualifizierungsmessreihe Robust even with temperature changes Temperature probes are exposed to harsh environmental conditions, such as changing temperatures and humidity, and should still work reliably in the field for 15 years or more. Checkmark
Qualifizierungsmessreihe Resistant to heat and humidity Extremely varying ambient conditions cause immense stress for the temperature probe and the design must be suitably robust and qualified.        
Qualifizierungsmessreihe Long-term stable in any weather Continuous exposure to sunlight, snow, fog, cold and ice shall not impair the function of the temperature probe and compliance with the specification.        
Qualifizierungsmessreihe Robust even under high vibration load Depending on the application, compressors and fans generate strong vibrations which are transmitted to components and cables. Therefore the used temperature probes have to be vibration resistant (20g). Checkmark
Qualifizierungsmessreihe Reliable in practice: high pull-out force The robust design ensures the necessary cable pull-out resistance, even under vibration and higher temperatures. Checkmark
Qualifizierungsmessreihe Efficient through short response time Depending on the application, short response times may be necessary to ensure efficient control of the system. Our sensor design is optimised for this requirement and we prove response times. Checkmark
Qualifizierungsmessreihe Corrosion-resistant even in salt spray Temperature probes are also used in coastal regions. For this reason, the temperature probes must also be able to withstand salty air for a lifespan of 15 years.        
Checkmark

Applicable for this probe type

Properties
Kalibrierung: DAkkS-Kalibrierung, ISO-Kalibrierung
Thermocouple: Type J Class 1
Temperature range: -40 °C to +750 °C
industry: Automotive, Building automation, Glass industry, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Power generation, Steel and iron industry
Related links to "Sheathed thermocouple type J with TC-connector"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Sheathed thermocouple type J with TC-connector"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Mantelthermoelement Typ J mit Leitung Vorderansicht Sheathed thermocouple type J with cable
23,80 € *
Order number: 802310-1111
Add to shopping cart
Mantelthermoelement Typ K mit TE-Stecker Vorderansicht Sheathed thermocouple type K with TC-connector
16,69 € *
Order number: 802311-1211
Add to shopping cart
Thermopaar Typ J Vorderansicht Thermocouple type J
9,48 € *
Order number: 803910-1111
Add to shopping cart