Delivery outside GER for business customers only
Quality directly from the manufacturer
Langzeitstabile Temperaturfühler über Jahre
Advice directly from experts
 

Sheathed thermocouple type J with cable

23,80 € *

Prices plus VAT plus shipping costs of 4,95 € to GER (incl. VAT)

Delivery time 5 Workdays to BE, AT, NL (GER -1 workdays)

Repeated order: check settings carefully and change if necessary.
1.Configure and order now
C - Length protection sleeve

Jeder Fühler benötigt eine Mindest-Eintauchtiefe, um die Temperatur des zu messenden Mediums annehmen und korrekt messen zu können. Faustformel: optimalerweise sollte die Eintauchtiefe 10-mal dem Schutzhülsendurchmesser entsprechen, mindest sollte jedoch ein 5-facher Wert verwendet werden.

keine Auswahl
(C0100) 100 mm
(C0150) 150 mm
(C0200) 200 mm
(C0250) 250 mm
(C0300) 300 mm
(C0400) 400 mm
(C0500) 500 mm
(C1000) 1000 mm
D - Diameter protection sleeve

Bei Temperaturmessungen in Festkörpern oder wenn der Fühler in einer Tauchhülse montiert ist, verlangsamt die den Fühler umgebende Luft die Wärmeleitung vom Medium zum Fühler. Dadurch wird auch die Temperaturmessung verlangsamt und führt im Extremfall zu falschen Temperaturmesswerten. Achten Sie bitte deshalb darauf, dass der Temperaturfühler wärmetechnisch bestmöglich an Ihr Messmedium angekoppelt ist, d.h. wählen Sie den Hülsendurchmesser so aus, dass der Luftspalt so klein wie möglich wird.

(D015) Ø 1,5 mm
(D030) Ø 3,0 mm
(D060) Ø 6,0 mm
E - Material connection cable

Bitte stellen Sie sicher, dass die technischen Daten der Anschlussleitung, insbesondere hinsichtlich Temperatur und IP-Schutzklasse, zu Ihrer Applikation passen. Detailierte Informationen finden Sie in unseren Datenblättern.
Temperaturbereiche unserer Leitungen:
PVC: -30 °C bis +90 °C
Silikon: -50 °C bis +180 °C
PFA: -50 °C bis +260 °C
Glasseide: -50 °C bis +400 °C

(E8010) PVC/PVC (2 x 0,22 mm²)
(E8210) FEP/SIL (2 x 0,22 mm²)
(E8510) PFA/PFA (2 x 0,22 mm²)
(E8310) GLS/VA (2 x 0,22 mm²)
F - Length connection cable
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
(F010) 1 m
(F020) 2 m
(F030) 3 m
(F040) 4 m
(F050) 5 m
(F100) 10 m
(F150) 15 m
(F200) 20 m
G - Connector

Bitte beachten Sie den spezifizierten Temperaturbereich des Stecker / der Aderendenhülsen
isolierte Aderendhülsen: bis 80 °C
Mini-TE-Stecker: bis 220 °C
TE-Stecker: bis 220 °C

(G01) Insulated end ferrules
(G01) Insulated end ferrules
(G11) Mini-TC connector J bk
(G31) TC connector J bk
H - Bend protection
(H0) Without (Standard)
(H0) Without (Standard)
Image Changer
2.Calibration

We can offer you calibration on request.
Further information on calibration can be found here.

Calibration

Didn't find the calibration you were looking for? Feel free to write to us at webshop@testo-sensor.de. 

Do you have further questions or want to find out which calibration is right for your temperature sensor? We have summarized all the information on this page for you. Calibrate temperature probes

Without calibration
ISO-Calibrationg
DakkS-Calibration
ISO-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

1-Point measurement (60 °C)
3-Point measurement (0 °C, 150 °C, 300 °C)
3-Point measurement (0 °C, 300 °C, 600 °C)
DAkkS-Calibration

Für individuelle Messpunkte oder spezielle Kalibrierungsanforderungen schreiben Sie bitte eine E-Mail an webshop@testo-sensor.de.

3-Point measurement (-20 °C, 0 °C, 60 °C)
3-Point measurement (0 °C, 100 °C, 200 °C)
3.How many probes do you need?
Price calculation
Basic price
23,80 €
C - Length protection sleeve:  
D - Diameter protection sleeve:  
E - Material connection cable:  
F - Length connection cable:  
G - Connector:  
H - Bend protection:  
Calibration:  
ISO-Calibration:  
DAkkS-Calibration:  
Quantity:  
Configuration is incomplete - please check it!
  • 802310-1111
Our Payments
MasterCardPayPalInvoiceVISAPrepayment

Advantages

Questions about the article?
Our employee will be happy to help you:
Julian Mäntele
Tel.: +49 (0)7653 96 59 771
E-Mail: jmaentele@testo-sensor.de
Sheathed thermocouples with cable are mineral insulated. We manufacture them from high-quality...more
Product information "Sheathed thermocouple type J with cable"

Sheathed thermocouples with cable are mineral insulated. We manufacture them from high-quality materials in a robust Type. They are flexible and can thus be used flexibly in the high temperature range from -40 °C to 750 °C.

Here you can find our downloads for the Sheathed thermocouple Type J with cable

pdf-download Data sheet Sheathed thermocouple Type J with cable
pdf-download Instruction manual Sheathed thermocouple Type J with cable
pdf-download Operating instruction Sheathed thermocouple Type J with cable
pdf-download Declaration of Conformity Sheathed thermocouple Type J with cable
step-download Step files Sheathed thermocouple Type J with cable
 

Sheathed thermocouple - General Information

Measuring range -40 °C to +750 °C
Perm. °C range cable see cable
Accuracy Class 1 1}: -40 °C bis +375 °C: ±1,5 °C | 375 °C bis 750 °C: ±0,004 |t| 2}
Pull-out force ≥ 30 N
1} according to DIN IEC 60584 2} If the thermocouple is operated outside the specified measuring range of its respective tolerance class, irreversible changes may also occur on the thermocouple, which subsequently leads to a measurement deviation (even within the specified range).
                                       

Sheathed thermocouple - Supply and output

Measuring element Thermocouple Type J
Measuring point Measuring point isolated
Measurement signal Thermovoltage
 

Sheathed thermocouple - Ambient conditions

Protection class IP42 according DIN 60529
Humidity and moisture condensation resistance according to application-specific qualification
 

Sheathed thermocouple - Certificates and Standards

Standards DIN EN 61326-1:2013 | DIN EN IEC 63000:2019-05
Directive RoHS 2011/65/EU | 2014/30/EU
 

Sheathed thermocouple - Technical Drawing

C - Length protection sleeve
D - Diameter protection sleeve
E - Material connection cable
F - Length connection cable
H - Bend protection
G - Connector
All dimensions in mm
 

Sheathed thermocouple - Protection sleeve

Material Stainless steel 1.4541 | SUS321
Diameter (mm)1} 1,5, 3, 6
Length (mm)2} 100, 150, 200, 250, 300, 400, 500, 1000
1} Tolerance ± 0,1 mm | 2} Tolerance ± 1%
 

Sheathed thermocouple - Connection sleeve

Material For Ø (D) 1.5 or 3: Stainless steel 1.4305 | SUS 303
For Ø (D) 6: Stainless steel 1.4301 | SUS 304
Z: Diameter (mm) For Ø (D) = 1.5 or 3: 5
For Ø (D) = 6: 7
Length (mm) 40
 

Sheathed thermocouple - Thermocouple cable

Type Color Material (Outside / Inside) Perm. range °C Ø Outside (mm) Cross section (mm²) Color strand Ω / m
Thermocouple cable Type J1} PVC / PVC -30 to +90 3,8 ± 0,2 0,22  bk, wt 2,502}
Thermocouple cable Type J1} FEP / Silicone -50 to +180 3,6 ± 0,2 0,22  bk, wt 2,502}
Thermocouple cable Type J1} PFA / PFA -50 to +260 2,6 ± 0,2 0,22  bk, wt 2,502}
Thermocouple cable Type J1} Glass fibre / Varnish -50 to +400 3,0 ± 0,2 0,22  bk, wt 2,502}
Length (m) 1, 2, 3, 4, 5, 10, 15, 20
Insulation resistance: ≥ 100 MOhm at min. 100 VDC | 1}Color according to IEC 584 | 2}per thermocouple | Cable available as accessory
 

Sheathed thermocouple - Connector

Insulated end ferrules (50 mm)
Mini-TC connector Type J bk
TC connector Type J bk
 

Sheathed thermocouple - Delivery

Assembly instructions by using an compression fitting or immersion sleeve
Delivery and Packaging Probe, seperatly packaged in PE bag
Matching accessories Immersion sleeve, Heat-conducting paste, Compression fitting
 

Sheathed thermocouple - Important assembly advices

Measurement errors can occur due to heat dissipation to the environment. To keep these as small as possible, we recommend immersing the protection sleeve of your temperature probe as deeply as possible into the medium to be measured during installation. The optimum installation depth should be 10-15 times the Ø of the protection sleeve or, when using an immersion sleeve, the Ø of the immersion sleeve. When installing in pipelines whose Ø does not have a sufficiently deep installation depth, you should install the probe either at an angle or in a pipe elbow. Make sure that there is sufficient space for the probe to be removed. 1) Installation with sufficient installation depth 2) Installation at an angle with small pipe Ø 3) Not like this: Minimum installation depth not reached

Installation by using an immersion sleeve (4): Please ensure that the Ø and length of the immersion sleeve are selected to suit the installation situation so that the minimum immersion depth can be achieved. Since the probe is not inserted directly into the medium, but via the immersion sleeve, the response times are somewhat slower. The probe should be selected in such a way that the protection sleeve touches the bottom of the immersion sleeve and that the air cushion around the protection sleeve is as small as possible. The use of thermal paste can improve the response times.

Please lay the cable with reserve loop (5). This allows you to extend the probe without disconnecting the electrical connection. Please pay attention to the bending radius. This should be at least 5 X D of the outer diameter of the sheathed thermocouple.

Properties
Kalibrierung: DAkkS-Kalibrierung, ISO-Kalibrierung
Thermocouple: Type J Class 1
Temperature range: -40 °C to +750 °C
Material cable: Glass fibre, PFA, PVC, Silicone
industry: Automotive, Cement and building materials industry, Glass industry, Heating technology, Machinery and apparatus engineering, Pharmaceutical industry, Plastics industry, Power generation, Steel and iron industry, Waste recycling/incineration, White goods
Related links to "Sheathed thermocouple type J with cable"
Available downloads:
Read, write and discuss reviews...more
Customer evaluation for "Sheathed thermocouple type J with cable"
Write an evaluation
Jede Verbraucherbewertung wird vor ihrer Veröffentlichung auf ihre Echtheit überprüft, sodass sichergestellt ist, dass Bewertungen nur von Verbrauchern stammen, die die bewerteten Produkte auch tatsächlich erworben/genutzt haben. Die Überprüfung geschieht durch manuelle Überprüfung in Form eines Abgleichs der Bewertung mit der Bestellhistorie des Warenwirtschaftssystems, um einen vorangegangenen Produkterwerb zur notwendigen Bedingung für die Veröffentlichung zu machen.
Please enter these characters in the following text field.
I have taken note of the Privacy Policy.

The fields marked with * are required.

Mantelthermoelement Typ K mit Leitung Vorderansicht Sheathed thermocouple type K with cable
23,80 € *
Order number: 802310-1211
Add to shopping cart
Mantelthermoelement Typ J mit TE-Stecker Vorderansicht Sheathed thermocouple type J with TC-connector
16,69 € *
Order number: 802311-1111
Add to shopping cart
Thermopaar Typ J Vorderansicht Thermocouple type J
9,48 € *
Order number: 803910-1111
Add to shopping cart